22 MMD 540H Hybrid Multimeter Meter Functions

Meter Functions – Duty Cycle (%)

ÑSelect the “%DUTY” Cycle function with the rotary switch.

Insert:

Ñ Black lead in COM

terminal.

 

 

Ñ Red lead in V-Ω-RPM

 

 

terminal.

 

 

Connect the Black test

 

 

probe to ground.

 

 

Connect the Red test probe

 

 

to the signal wire circuit.

 

 

The illustration for a mixture

 

 

control solenoid is shown

 

 

with the metering rod in the

 

 

closed position. The meter

 

 

will display the percentage

 

 

of time the plunger is in the

 

 

closed position. (low duty

 

 

cycle) during one duty cycle.

Black–

Red+

Mixture

Control

Shown

Robert Bosch LLC