Bosch Appliances PLE-10M2-US manual 2.4.3Rear panel, en, The unit must be grounded

Models: PLE-10M2-US

1 34
Download 34 pages 39.85 Kb
Page 12
Image 12
2.4.3Rear panel

Plena Easy Line Mixer Installation and User Instructions Description

en 12

2.4.3Rear panel

See figure 2.3 for an overview of the connectors and switches:

1 Microphone/line 1 input with trigger, Euro style pluggable screw terminal connector - DIP switch settings for: chime, PTT (push to talk), mic/line, speech filter, and phantom power (see number 2).

2DIP switch for microphone/line 1 and microphone/ line 2 (see numbers 1 and 3, respectively).

3Microphone/line 2 input, Euro style pluggable screw terminal connector - DIP switch settings for speech filter, mic/line, VOX, and phantom power (see number 2).

4Microphone/line 3 input, Euro style pluggable screw terminal connector - DIP switch settings for mic/line, and phantom power (see number 5).

5DIP switch for microphone/line 3 and microphone/ line 4 (see numbers 4 and 6 respectively).

6Microphone/line 4 input, Euro style pluggable screw terminal connector - DIP switch settings for mic/line,

and phantom power (see number 5).

7Microphone/line 5 input, Euro style pluggable screw terminal connector - DIP switch settings for mic/line,

and phantom power (see number 8).

8 DIP switch for microphone/line 5 and microphone/ line 6 (see numbers 7 and 9 respectively).

9Microphone/line 6 input, Euro style pluggable screw terminal connector - DIP switch settings for mic/line, and phantom power (see number 8).

10Mains voltage switch, C13 - 115/230 VAC 50/60 Hz.

11Tel. emergency/70V input, Euro style pluggable screw terminal connector - VOX function. This input has highest priority.

12Telephone emergency/70V input volume control - control range -25 dB to 0dB (see number 11).

13Chime volume control for microphone/line input 1 (see number 1).

14Ducking level control for microphone/line inputs 1 and 2.

15Call station input, RJ-45 connector - PLE-2CS or PLE-2CSMM, chimes are in call station. This input has second highest priority.

16Remote control wall-panel-input, RJ-45 connector. Wall panel incorporates: BGM source selection, and zone on/off control.

17Music input (number 1 disc), 2x RCA/cinch connectors. Stereo, summed mono.

18Music input (number 2 radio), 2x RCA/cinch connectors. Stereo, summed mono.

19Music input (number 3 auxiliary), 2x RCA/cinch connectors. Stereo, summed mono.

20Pre-out, amp in insert, 2x RCA/cinch connector - can be used for EQ or feedback suppressor.

21Master switch for line out or music (see number 22).

22Music master output, Euro style pluggable screw terminal connector - switch setting for line out, or music only (see number 21).

2324 VDC input and volume override output:

24 VDC backup power input - Euro style pluggable screw terminal connector.

Volume override output - Euro style pluggable screw terminal connector.

24Zone 1 output, Euro style pluggable screw terminal connector, balanced.

25Zone 2 output, Euro style pluggable screw terminal connector, balanced.

26Mains fuse.

27Ground connection screw.

Note

The unit must be grounded.

28 Mains connector (3-pole).

Bosch Security Systems 2008-04 PLE-10M2-US en

Page 12
Image 12
Bosch Appliances manual 2.4.3Rear panel, The unit must be grounded, Bosch Security Systems 2008-04 PLE-10M2-USen