UHI-SBG-0 Series | Installing the Housing | 5 |
| | |
5 Installing the Housing
This chapter outlines the procedures needed to install the UHI-SBG-0 Indoor Housing Series. Installation should be made by a qualified service person and all local codes should be con- formed to.
5.1Opening the Cover
The UHI-SBG-0 housing is secured with two (2) tamper-resistant screws. To open the cover, use the supplied tamper-resistant wrench to remove the screws.
Fig. 5.1 Opening the Cover
5.2Feed-through Wiring
The UHI-SBG-0 features feed-through wiring holes which are used to feed the cabling through. Prior to mounting the camera, remove the rear (2) or bottom (2) rubber dome plugs and install the NPT fittings (see Section 5.3: NPT Fittings).
5.3NPT Fittings
The NPT fittings ensure a tight seal. Depending on how the UHI-SBG-0 is mounted, the NPT fit- tings can be installed either in the rear or from the bottom of the housing. The supplied 3/8 in. NPT fittings accept a round cable with diameters from 4.3 mm (0.17 in.) to 11.4 mm (0.45 in.). The two larger 1/2 in. NPT fittings accept cables with diameters from 6.5 mm (0.26 in.) to 10.5 mm (0.42 in.).
Fig. 5.2 Installing the NPT Fittings
Screw Nut (discard if using 3/8 in. NPT for bottom openings)
Rubber Washer
NPT Fitting
Sealing Nut
Fig. 5.3 NPT Exploded View
Bosch Security Systems, Inc. | Installation Manual | September 15, 2006 F01U032279_01 |