8 | en Advanced Setup | AutoDome 100 Series Fixed Camera |
|
|
|
NOTICE!
To restore a selected menu item to its factory default, quickly press the Menu Select key twice.
To exit the OSD menus from any menu item, hold down the Menu Select key until the OSD disappears.
The
–A Universal keyboard using Bilinx over coax or UTP. For example, using a Bosch DiBos 8, a Bilinx capable DIVAR, or an Allegiant system.
–A PC running the optional Bosch Configuration Tool for Imaging Devices (CTFID) software with a USB Bilinx adapter (Part No.
NOTICE!
To prevent unauthorized changes to the camera settings, the camera menu buttons can be disabled using Bilinx communication through the CTFID software. Select the Online Config button, then select the Miscellaneous branch and set Camera Buttons to Disable.
4.2 | Main Menu Function |
| This section provides a graphical representation of the Main menu and descriptions for all |
functions.
MAIN Menu
ALC ENHANCE COLOR BLC EXIT
ALC
ALC LEVEL
SHUT GAIN PEAK AVERAGE ALC SPEED EXIT
ENHANCED
AUTO BLACK SHARPNESS DNR
EXIT
COLOR
WHITE BALANCE WB SPEED RED (GAIN)
GREEN BLUE (GAIN)
SAT
EXIT
BLC
BLC
BLC LEVEL
BLC AREA
EXIT
SHUTGAIN
SHUTTER
DEFSHUT
FIXSHUT
SENSUP GAIN MAXGAIN FIXGAIN DAY/NIGHT1 NIGHTSENSE EXIT
AREA
DAY/NIGHT
DAY/NIGHT SWITCH LVL
PRIORITY
IR CONTRAST MONO BURST EXIT
1.Available in Day/Night version cameras only, other versions show NightSense.
2.Only available when White Balance is set to Manual mode.
F.01U.216.346 1.0 2011.04 | User Manual | Bosch Security Systems, Inc. |