14 en InstallationVIP X1600 XF
4.3 | Installing in a Switch Cabinet |
4.3.1 | Preparations |
| The VIP X1600 XF is set up for installation in a |
| equipment is included in the scope of delivery. |
CAUTION!
When installing in a switch cabinet, ensure that there is sufficient ventilation for the unit. There must be at least 5 cm (1.97 in.) of free space to the left and right of the unit and at least
!10 cm (3.94 in.) at the rear.
The VIP X1600 XF generates heat during operation. During installation, please note the maximum heat value of 170 BTU/h.
When mounting additional units, direct contact with the VIP X1600 XF is permitted, provided that the surface temperature of the adjacent units does not exceed +50 °C (+122 °F).
When installing in a switch cabinet, ensure that the screw joints are free of tension and subject to as little mechanical stress as possible. Ensure that the unit and the power supply units have sufficient grounding.
4.3.2Installing and Connecting the VIP X1600 XF
! | CAUTION! | |
Only use power supply units approved by Bosch Security Systems. | ||
|
1. Prepare the switch cabinet in such a manner that you are easily able to insert the VIP X1600 XF directly at the installation point.
2. Place the cage nuts in the corresponding drillings or spaces in the switch cabinet frame.
3. Lift the VIP X1600 XF into the switch cabinet frame and insert the fastening screws together with the washers.
4. Tighten the screws one after the other and then check once more that all the screws are tight.
5. Connect one or two power supply units to the sockets on the rear of the housing and hand tighten the coupling nuts for the plug.
F.01U.082.088 V3.5 2008.05 | Installation and Operating Manual | Bosch Security Systems |