Bosch Power Tools 125 manual Working Advice, Troubleshooting, Autostop function, Stopping, General

Models: 125

1 15
Download 15 pages 44.96 Kb
Page 12
Image 12
Autostop function

12 English

Autostop function

The machine is designed to switch off the motor when the trigger 9 is released on the gun. This feature relieves high pressure from the system to achieve a longer lifetime and lower energy consumption. (A short squeaking noise can oc- cur and is completely normal.)

Stopping

Release trigger 9. Press the trigger safety lock 10. The power gun is now locked and can not be operated accidentally.

Press on/off switch 4.

Close water tap. Unplug the machine from the mains supply.

Press the trigger safety lock 10 to release the trigger 9. Fully press the trigger 9 until there is no more water pressure in the machine. Release trigger 9. Press the trigger safety lock 10.

Disconnect water supply hose from machine and water supply.

Self priming function

The machine can also operate with water from sources other than a water tap, e. g. ponds and water butts due to the self priming function. The use of an additional water filter (not supplied) is highly recommended for this kind of use.

Make sure the water source is situated no more than 1 m below the level of the machine.

Fill water supply hose (not supplied) with water before connecting it to the machine. Running the machine without water (running dry) will damage it.

Run machine without lance attached until there is a constant flow of water.

Turn off machine and connect lance.

Working Advice

General

Ensure that the pressure washer is on level ground.

Do not kink or drive a motor vehicle over the high pressure hose. Do not expose the high pressure hose to sharp edges or corners.

Never use the roto jet mode to clean motor vehi- cles.

Troubleshooting

The following chart lists problem symptoms, possible causes and corrective action, if your pressure washer does not operate properly. If these do not identify and correct the problem, contact your service agent.

fWarning: Switch off and remove plug from mains before investigating fault.

Problem

Possible Cause

Corrective Action

Motor refuses to start

Plug not connected

Connect plug

 

 

 

 

Mains socket faulty

Use another socket

 

 

 

 

Fuse faulty/blown

Replace fuse

 

 

 

 

Extension cable damaged

Try without extension cable

 

 

 

Motor stops

Fuse faulty/blown

Replace fuse

 

 

 

 

Wrong mains voltage

Check that mains voltage corre-

 

 

sponds to specifications on the

 

 

model tag

 

 

 

F 016 L70 545 (14.1.11)

Bosch Power Tools

Page 12
Image 12
Bosch Power Tools 125 manual Working Advice, Troubleshooting, Autostop function, Stopping, Self priming function, General