BM 1609929H54 08-06 8/3/06 11:44 AM Page 12

Maintenance

Service

Preventive maintenance ! WARNING performed by unauth-

orized personnel may result in misplacing of internal wires and components which could cause serious hazard. We recommend that all tool service be performed by a Bosch Factory Service Center or Autho- rized Bosch Service Station.

TOOL LUBRICATION

Your Bosch tool has been properly lubricated and is ready to use. It is recommended that tools with gears be regreased with a special gear lubricant at every brush change.

CARBON BRUSHES

The brushes and commutator in your tool have been engineered for many hours of dependable service. To maintain peak efficiency of the motor, we recommend every two to six months the brushes be examined. Only genuine Bosch replacement brushes specially designed for your tool should be used.

BEARINGS

After about 300-400 hours of operation, or at every second brush change, the bearings

should be replaced at Bosch Factory Service Center or Authorized Bosch Service Station. Bearings which become noisy (due to heavy load or very abrasive material cutting) should be replaced at once to avoid overheating or motor failure.

Cleaning

!WARNING To avoid accidents always disconnect the tool from

the power supply before cleaning or performing any maintenance. The tool may be cleaned most effectively with compressed dry air. Always wear safety goggles when cleaning tools with compressed air.

Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not attempt to clean by inserting pointed objects through openings.

!CAUTION Certain cleaning agents and solvents damage

plastic parts. Some of these are: gasoline, carbon tetrachloride, chlorinated cleaning solvents, ammonia and household detergents that contain ammonia.

Accessories

!If an extension cord is WARNING necessary, a cord with

adequate size conductors that is capable of carrying the current necessary for your tool must be used. This will prevent excessive voltage drop, loss of power or overheating. Grounded tools must use 3-wire extension cords that have 3-prong plugs and receptacles.

NOTE: The smaller the gauge number, the heavier the cord.

RECOMMENDED SIZES OF EXTENSION CORDS 120 VOLT ALTERNATING CURRENT TOOLS

Tool’s

Cord Size in A.W.G.

Wire Sizes in mm2

 

 

 

 

 

 

 

 

Ampere

 

 

 

 

 

 

 

 

Cord Length in Feet

Cord Length in Meters

Rating

25

50

100

150

15

30

60

120

 

3-6

 

 

 

 

 

 

 

 

18

16

16

14

0.75

0.75

1.5

2.5

6-8

18

16

14

12

0.75

1.0

2.5

4.0

8-10

18

16

14

12

0.75

1.0

2.5

4.0

10-12

16

16

14

12

1.0

2.5

4.0

12-16

14

12

 

 

 

 

 

 

 

 

 

*

Wheel guard

** Grinding wheel

*

Side handle

** Backing flange (sanding)

** Lock nut wrench (grinding)

** Rubber backing pad (sanding)

** Backing flange (grinding)

** Lock nut wrench (sanding)

** Lock nut (grinding)

 

(*= standard equipment)

Wheel guard must be used when sander

(**= optional accessories)

is converted for grinding operations.

-12-

Page 12
Image 12
Bosch Power Tools 1873-8F, 1894-6, 1873-6, 1893-6 manual Maintenance, Accessories, Cleaning