Operation | Falcon 36 Operation Manual |
2SHUDWRU&RQWUROV
The operator controls for the Falcon 36 Laminator are located on the front and rear of the unit, to the right of the operator position. The names and functions of these controls are as follows:
)URQW &RQWURO 3DQHO
Speed Adjustment
MOTOR |
| |
FWD | 9 | AUTO |
|
| |
6 | 12 |
|
7.POWER LIGHT – Indicates when the main power is being applied to the machine.
8.UPPER ROLL HEATER CONTROLLER – Provides a readout of the temperature of the upper roll and the
9.LOWER ROLL HEATER CONTROLLER– Provides a readout of the temperature of the lower roll and the
Motion Control | 1 | 3 | 2 | 15 | 6 | Foot Switch/ |
FORWARD/ |
| 0 |
| 18 |
| Continuous Run |
REVERSE |
|
|
| AUTO/STOP | ||
REV | SPEED | STOP | ||||
| FANS |
|
|
|
|
|
| 1 |
|
| POWER |
| |
Cooling Fans | 3 |
|
|
| 7 | Power Light |
ON/Off | O |
|
|
| ||
|
|
|
|
| ||
. |
|
| HEATERS |
| ||
|
|
|
| |||
| 1 |
| OUT | 175 | HI |
|
|
|
| 150 | 200 |
| |
| T | 125 |
| 225 |
| |
|
|
|
| |||
Upper Roll Heat | 4 |
| 8 |
| Top Roll Heater | |
O | 100 | 250 | ||||
75 | 275 | |||||
|
| P |
|
|
|
|
|
| OUT | 175 | HI |
| ||
|
|
| 150 |
| 200 |
|
|
Red: Set point has |
|
|
|
| |||
not been reached | 125 |
| 225 |
| |||
Green: Temperature |
|
| |||||
|
|
|
|
|
| ||
is exactly at set point | 100 |
|
| 250 |
| ||
|
|
|
|
| |||
|
| 75 |
| 275 |
| ||
|
| 50 | °F | 300 |
|
| |
|
|
|
| ||||
|
| PROTECH |
|
Solid: Temperature is within 5° of set point
Blinking: Temperature is greater than 5° of set point
Off: Set point has been reached or exceeded
Solid: Temperature is within 5° of set point
Blinking: Temperature is lower than 5° of set point
ON/OFF | O |
|
| 50 | °F | 300 |
| Controller | |
|
|
| B | PROTECH |
|
| |||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |
| 1 |
| OUT | 175 |
| HI |
|
| |
|
| 150 |
| 200 |
|
| |||
|
| O | 125 |
| 225 |
|
| ||
Lower Roll Heat |
| 5 | T | 100 | 9 |
| 250 |
| Lower Roll Heater |
| T | 75 |
| 275 |
| ||||
ON/OFF | O |
| O | 50 |
| 300 |
| Controller | |
|
|
| M | PROTECH | °F |
|
| ||
|
| GBC |
|
|
Figure
1.SPEED ADJUSTMENT – Adjusts the speed of the machine from zero to the maximum as the control is turned clockwise.
2.MOTION CONTROL FORWARD/REVERSE - Controls the direction of the drive system, forward, reverse, or stop.
3.COOLING FANS ON/OFF – Turns the cooling fans on or off and turns the vacuum table fans on or off, when a vacuum table option is installed.
4.UPPER ROLL HEAT ON/OFF – Turns the heater controller for the upper main roll on or off.
5.LOWER ROLL HEAT ON/OFF – Turns the heater controller for the lower main roll on or off.
6.FOOT SWITCH/CONTINUOUS RUN AUTO/STOP - Changes control of the machine drive from a foot switch to continuous run.
Off: Set point has been reached or exceeded
Figure
5HDU 3DQHO &RQWURO
MOTOR
AUTO
Foot Switch/
Continuous Run
AUTO/STOP
STOP
Figure
FOOT SWITCH/CONTINUOUS RUN AUTO/STOP - Changes control of the machine drive from a foot switch to continuous run.
WARNING
Use extreme caution when operating the
laminator with the footswitch. The
photoelectric eye system is overridden and your fingers can get caught in the nip. You can be crushed or burned.
© GBC |