Falcon 36 Laminator Service Manual | Safety and Warranty Information |
WARNING
Exercise care when cleaning the rolls with80% isopropyl alcohol:∙Use only in a well ventilated area.∙Wear rubber gloves.∙Use only on cool rolls.Cleaning heated rolls can ignite the fumes.CAUTION
Use only 80% isopropyl alcohol or a rubber cement eraser to clean the laminating rolls.
Harsh chemicals like toluene, acetone or MEK destroy the silicone covering of the rolls.
CAUTION
Raise the upper main roll when thelaminator is not in operation. Prolongedcontact can damage the rolls.CAUTION
Excess pressure can damage the laminatingrolls. Always select the minimum roll pressure necessary to complete the task.
CAUTION
If silicone adhesive contacts the upper or lower roll, remove it IMMEDIATELY using 80 % isopropyl alcohol. It can harden within an hour and ruin the roll.
WARNING
The operating environment must be free of dust, flammable liquids and vapors. You can be injured by inhaling chemical vapors. Vapor build up or stored flammable liquids can cause a fire. Excessive dust can damage the laminator.
CAUTION
Do not use a knife or other sharp instrumentduring installation or while servicing the laminator. You can cause irreparable damage to the rolls.
WARNING
Do not attempt to move the laminator acrossanything other than a flat, level surface without trained and qualified riggers. You can be crushed or seriously injured.
The Falcon 36 Laminator is a large and heavy piece of equipment. It is necessary to employ LICENSED RIGGERS ONLY to move the machine. The laminator is not designed to be tipped up or sideways in any way. Such action disturbs the exact alignment of the rolling parts of the machine and requires extensive realignment. GBC
GBC
© GBC |