Exiting Special Modes

A press of 11 ON/CLEAR/OFF for less than 1 second while the tool is in the SIMPLE MTR or COMPOUND MTR modes (or when HOLD [mem- ory] is flashing) returns the tool to the normal measuring mode.

Operation

Normal Measuring Mode – Measuring the Angle of Structure or Workpiece (See Figure D–F)

1Place both legs flat on the sur- faces adjacent to the angle.

2The “tool-interior angle” w (the angle between the main leg 6 and the adjustable leg 2) is measured.

3The angle measurement in degrees is shown in the display.

Notes:

Contact surfaces and contact edges must be clean. A dirty surface will cause erroneous measurements.

For increased ability to see the measurement, there are displays on both the front and back sides of the tool.

When the angle between the legs is changed, the angle mea- surement displayed is automati- cally updated.

Using the Leg Extension (Optional Attachment)

The leg extension makes it possible to measure convex angles when one of the contact surface areas is too short to accommodate the length of the legs.

Slide the leg extension 14 onto the adjustable leg 2 in the direc- tion indicated by the arrow on the extension.

2 609 140 572 (8.9.08)