BM 2609140574 08-08 9/3/08 8:40 AM Page 4

Technical Data

 

 

DIGITAL MULTI-DETECTOR DMD4

 

 

Article number

3 601 K10 010

Maximum scanning depth*:

 

 

Ferrous metals

4" / 100 mm

Non-ferrous metals (copper)

3-1/8" / 80 mm

Copper wiring (live)

2" / 50 mm

Wood Substructures (studs)

3/4" / 20 mm

Automatic switch-off

After approx. 5 min

Operating temperature

14 °F

122 °F

 

–10 °C

+50 °C

Storage temperature

– 4 °F

–158 °F

 

–20 °C

+70 °C

Battery

1 x 9 V 6LR61

Rechargeable battery

1 x 9 V 6F22

Operating lifetime (alkali-manganese batteries)

Approx. 6 h

Weight according to EPTA-Procedure 01/2003

0.53 lbs/ 0.24 kg

*Depends on material and size of objects as well as material and condition of structure.

**Less scanning depth for wires/conductors that are not “live”.

Please observe the article number on the type plate of your multi-detector.

Preparation

INSERTING/REPLACING THE BATTERY Use only alkali-manganese or rechargeable batteries.

To open the battery lid 10, press the latch 12 in the direction of the arrow and fold up the battery lid. Insert the supplied battery. Pay attention that the polarity is correct, according to the + and - symbols on the inside of the battery lid.

When the battery indication k in the display lights up, measuring is possible for approx. 1 h when using alkali-manganese batteries (service life is shorter with rechargeable batteries).

When the battery indication k flashes, measuring is still possible for approx. 10 minutes.

When the battery indication k and the illuminated ring 1 (red) are flashing, measuring is no longer possible and the battery or the rechargeable battery respectively, must be replaced.

If the multi-detector is not used for a long period of time, the battery must be removed. The battery can corrode or discharge itself over long periods.