Water connections continued-

If this water heater is installed in a closed water supply system, such as the one having a back-flow preventer in the cold water supply, provisions shall be made to control thermal expansion. DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion. Your water supplier or local plumbing inspector should be contacted on how to control this situation.

After installation of the water lines, open the main water supply valve and fill the water heater. While the water heater is filling, open several hot water faucets to allow air to escape from the water system. When a steady stream of water flows through the faucets, close them and check all water connections for possible leaks. NEVER OPERATE THE WATER HEATER WITHOUT FIRST

BEING CERTAIN IT IS FILLED WITH WATER.

WARNING

For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements of the Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 or the Standard CAN1-4.4. Temperature and Pressure and the Standard CAN1-4.4, Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves. The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater. The combination temperature and pressure relief valve shall also have an hourly rated temperature steam BTU discharge capacity not less than the hourly rating of the water heater.

Install the combination temperature and pressure relief valve into the opening provided and marked for this purpose on the water heater.

Note: Some models may already be equipped or supplied with a combination temperature and pressure relief valve. Verify that the combination temperature and pressure relief valve complies with local codes. If the combination temperature and pressure relief valve does not comply with local codes, replace it with one that does. Follow the installation instructions above on this page.

Install a discharge line so that water discharged from the combination temperature and pressure relief valve will exit within six (6) inches (15.2 cm) above, or any distance below the structural floor and cannot contact any live electrical part. The discharge line is to be installed to allow for complete drainage of both the combination temperature and pressure relief valve and the discharge line. The discharge opening must not be subjected to blockage or freezing. DO NOT thread, plug or cap the discharge line. It is recommended that a minimum clearance of four

(4)inches (10.2 cm) be provided on the side of the water heater for servicing and maintenance of the combination temperature and pressure relief valve.

Do not place a valve between the combination temperature and pressure relief valve and the tank.

11

Page 11
Image 11
Bradford-White Corp 238-37281-00R instruction manual Being Certain IT is Filled with Water

238-37281-00R specifications

Bradford-White Corp has long been recognized as a leader in the water heating industry, and the 238-37281-00R is a prime example of their commitment to quality and innovation. This specific model is designed for residential applications, offering efficient performance tailored to meet the needs of modern households.

One of the standout features of the 238-37281-00R is its Energy Star rating, which signifies its superior energy efficiency compared to traditional water heaters. This translates to reduced energy bills and a lesser environmental footprint, appealing to energy-conscious consumers looking to save on costs while still enjoying reliable hot water access.

The unit operates with advanced technology that enhances its overall performance. It is equipped with a vortex combustion system that improves efficiency by ensuring complete combustion, minimizing wasted energy. This technology also contributes to quieter operation and increased safety by reducing the risk of gas leaks.

In terms of design, the Bradford-White 238-37281-00R is built with durability in mind. It features a robust tank made from high-grade materials that resist corrosion, ensuring a longer lifespan. The insulation used in the tank is also top-notch, reducing heat loss and improving energy retention, which ultimately leads to increased efficiency.

Installation is straightforward, thanks to the compact design of the unit. It offers versatility in terms of placement, making it suitable for a variety of home configurations. Homeowners can install it in tight spaces without compromising on performance or efficiency.

Another important characteristic of this model is its maintenance-friendly design. Bradford-White provides access to critical components for easy servicing, which can prolong the life of the water heater and maintain performance over time.

Additionally, the 238-37281-00R includes advanced safety features, such as a temperature and pressure relief valve, and an integrated control system that monitors and responds to any potential issues, giving homeowners peace of mind.

Overall, the Bradford-White Corp 238-37281-00R stands out due to its combination of efficiency, durability, and safety. It embodies the company's dedication to delivering high-quality water heating solutions that cater to the needs of today's consumers. With its advanced technologies and user-friendly design, it represents an excellent investment for anyone in search of a reliable water heating option.