Bradford-White Corp 720-B Copper-Brute II 500-2000 Water Heater Specifications, Water Flow Data

Models: 720-B

1 6
Download 6 pages 16.06 Kb
Page 5
Image 5
Copper-Brute II (500-2000) Water Heater Specifications

Copper-Brute II (500-2000) Water Heater Specifications

1 2 3

B W C

SERIES

4

V

USAGE

V

5 6 7 8

SIZE

0

5

0

0

0

7

5

0

1

0

0

0

1

2

5

0

1

5

0

0

1

7

5

0

2

0

0

0

9

FUEL

N

P

10

 

 

11

 

12

 

 

13

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

 

LOCATION

 

FIRING

 

REVISION

 

A

 

 

 

 

 

 

MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K=Two-Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C=Convertible

 

N=Three-Stage

 

 

 

 

 

 

 

 

 

 

L=Four-Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

HEAT

EXCHANGER

B(std.)

K P S

15

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS

 

PUMP

CODE

 

OPTIONS

X (std.)

 

N (std.)

 

J

 

 

S

 

L

 

 

H

Model Character Designation

(1-3) Model Series Designation

B W C = Copper Brute II

(4) Usage

V = Volume Water

(5-8) Size

0 5 0 0 = 500,000 BTU/Hr. input

0 7 5 0 = 750,000 BTU/Hr. input

1 0 0 0 = 999,000 BTU/Hr. input

1 2 5 0 = 1,250,000 BTU/Hr. input

1 5 0 0 = 1,500,000 BTU/Hr. input

1 7 5 0 = 1,750,000 BTU/Hr. input

2 0 0 0 = 1,999,000 BTU/Hr. input

(9) Fuel

N = Natural Gas

P = Propane

(10) Altitude

A = 0-10,000 feet

(11)Location C=Convertible

(12)Firing Mode

K = Two-stage (500 & 750)

N = Three-stage (1000)

L = Four-stage

(1250, 1500, 1750 & 2000)

(13) Revision

2 = First Revision of Design

(14) Heat Exchanger

B = Glass-lined cast iron headers / copper tubes/ bronze trim

K = Bronze headers / copper tubes/ bronze trim

P = Glass-lined cast iron headers / cu-nickel / bronze trim

S = Bronze headers / cu-nickel / bronze trim

(15)Option Code X = Standard

J = CSD-1, FM, IRI, IL

L = LDS (consult factory)

(16)Pump Options

N = Pump mounted water heater, normal water pump

S = Pump mounted water heater, soft water pump

H = Pump mounted water heater, hard water pump

Copper-Brute II Models

 

 

 

WATER TEMPERATURE RISE IN DEGREES

 

Gas2

Water2

Shipping

Model

Input 1

Output1

90°F

50°C

100°F

56°C

140°F

78°C

Conn.

Conn.

Weight

Numbers

BTU/Hr.

BTU/Hr.

GPH

LPH

GPH

LPH

GPH

LPH

inches

inches

(lbs.)

(kg)

BWCV0500

500,000

425,000

567

2143

510

1929

364

1378

114

2

480

218

BWCV0750

750,000

638,000

850

3214

765

2893

547

2066

114

2

560

254

BWCV1000

999,000

849,000

1133

4281

1019

3853

728

2752

112

212

670

304

BWCV1250

1,250,000

1,063,000

1417

5357

1276

4821

911

3444

2

212

730

331

BWCV1500

1,500,000

1,275,000

1701

6429

1531

5786

1093

4133

2

212

815

370

BWCV1750

1,750,000

1,488,000

1984

7500

1786

6750

1276

4821

2

212

880

400

BWCV2000

1,999,000

1,699,000

2266

8567

2040

7710

1457

5507

2

212

1010

459

1.Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.

2.Dimensions are nominal.

Note: GPH = gallons per hour, LPH = liters per hour.

Water Flow Data

 

HARD WATER

NORMAL WATER

SOFT WATER

Model

Flow

Flow

Flow

Flow

Flow

Flow

Numbers

GPM

LPM

GPM

LPM

GPM

LPM

BWCV0500

90

341

68

257

45

170

BWCV0750

90

341

68

257

45

170

BWCV1000

90

341

68

257

45

170

BWCV1250

90

341

68

257

68

257

BWCV1500

90

341

68

257

68

257

BWCV1750

90

341

68

257

68

257

BWCV2000

112

424

112

424

112

424

 

 

 

 

 

 

 

Firing Rates

Model Numbers

Firing Stage

BWCV0500

2-Stage

BWCV0750

2-Stage

BWCV1000

3-Stage

BWCV1250

4-Stage

BWCV1500

4-Stage

BWCV1750

4-Stage

BWCV2000

4-Stage

Note: GPM= gallons per minute, LPM=liters per minute