Bradford-White Corp PDV80S250, D80T725 To Display Flame Sense Current of the Pilot Flame Sensor

Models: PDV80T300 PDV100S150 PDV100T360 PDV80S150 D65T625 PDV802200 PDV80S250 PDV100S250 PDV100S200 D80T725

1 52
Download 52 pages 26.59 Kb
Page 15
Image 15

Step 3: For water heaters using two temperature sensors, pressing the “Select” button again displays the Lower Sensor temperature reading. “Lower Sensor” will be displayed in the lower left side of the status window of the water heater display.

°F

idle

Status Operational

Lower Sensor

SELECTSET

To Display Flame Sense Current of the Pilot Flame Sensor:

The pilot flame sense current is available only when the burners are in operation. Step 1: Make sure the status displays

“Heating” or draw enough hot water to start the burners. Step 2: Enter the “Service Mode” described previously. Step 3: Press the “Select” button until a number value is displayed with “Flame Current” to the right of the number. The value displayed is in microamps (µA).

Flame

Current

µA

Heating

Status Operational

SELECTSET

To Display and Change Temperature Setpoint:

Step 1: In “Service Mode” press the “Select” button until “Setpoint” is shown in the water heater display

°F setpoint

idle

Status Operational

SELECTSET

15

Page 15
Image 15
Bradford-White Corp PDV80S250, D80T725, D65T625, PDV100S150 To Display Flame Sense Current of the Pilot Flame Sensor