Specifications

Power Supply

Dedicated 120 VAC, 60 Hz., 15 A

Current Draw

Less than 5 Amps

PDV-S & PDV-T MODELS: 3/4" NPT Minimum connection to gas valve.

Gas Supply Connection INDUCED DRAFT MODELS: 1" NPT Minimum conncection to gas valve. Schedule 40 black iron pipe recommended for all models.

Approved Gas Type

Gas Pressure (Nat. & L.P.)

Venting System

Minimum Clearance for Servicing

Maximum Water Supply Pressure

Thermostat Sensor(s)

Control Board

Control Display

Natural or Propane. Gas supply must match the gas type listed on the water heater rating label.

Manifold Pressure: 4.5" w.c. natural gas, 10.0" w.c. L.P.

Gas Supply Pressure: At least 1" above manifold pressure with water heater operating, 14" w.c. maximum

PDV-S MODELS:

Power vented through either 3" or 4" diameter PVC, CPVC, or ABS pipe for 150,000 or 199,999 Btu/hr. models, 4" only for 250,000 Btu/hr. models. Refer to the installation instruction manual for further information on venting lengths and installation requirements.

PDV-T MODELS:

Power vented through Co-axial Venting (pipe inside a pipe) - Combustion air enters from the outside the building through an outer pipe (200mm diam.) and exhausts flue products through the inside pipe (130mm diam.). Refer to the installation instruction manual for further information on venting lengths and installation requirements.

INDUCED DRAFT MODELS:

Connect 8” vent to blower vent collar for venting through a chimney or type B vent only. Vertical venting only.

30" Front Clearance, 16" Top, 2" Sides and Rear

150 PSI

Redundant thermister with 11,900 + or - 0.5% ohms resistance at 70 deg. F. Sensor inside well for lower sensor. PDV-T model series and Induced Draft models also use an upper sensor (dual sensors for these models).

Honeywell Integrated Control Board for Temperature Control, Induced Draft Blower, and Ignition Control Functions. Operates on 24 volts AC current from transformer. Single sensor boards for PDV-S models and dual sensor boards for PDV-T models and Induced Draft models.

Honeywell LCD Control Display with Temperature Setpoint, Format, and Error Code Display in User Mode, Diagnostic Functions in Service Mode. Communicates with Control Board. 24 volts AC. Same control display used on all models.

Transformer

Pilot

Induced Draft Blower

120 VAC Primary, 24 VAC Secondary, 40 VA

Intermittent Pilot with Spark Electrode and Flame Sensor monitored by Control Board

PDV-S MODELS: 115 VAC, 60 Hz., 4.3 Amps.

PDV-T MODELS AND D80T725, D65T625: 115 VAC, 60 Hz., 3.6 Amps.

5

Page 5
Image 5
Bradford-White Corp PDV80S250, D80T725, D65T625, PDV100S150, PDV100S250, PDV100T360, PDV80T300, PDV802200 Specifications

PDV80T300, PDV100S150, PDV100T360, PDV80S150, D65T625 specifications

Bradford-White Corporation is renowned for its quality water heating solutions, with a diverse range of products designed to meet various residential and commercial needs. Among their stellar offerings are the D80T725, PDV100S200, PDV100S250, PDV80S250, and PDV802200 models, each equipped with advanced technologies and features that set them apart in the market.

The D80T725 is an innovative 80-gallon water heater that employs a powerful 75,000 BTU burner, ensuring rapid water heating for larger households. One of its key features is the Defender Safety System, which provides exceptional protection against potential hazards. The advanced electronic control system enhances efficiency and reliability, making it an ideal choice for energy-conscious consumers. Additionally, the tank's unique insulation helps maintain water temperature longer, reducing energy costs.

Moving to the PDV series, the PDV100S200 and PDV100S250 are dynamic, direct vent gas water heaters with capacities of 100 gallons and impressive BTU inputs. These models utilize a proper venting system that draws air from outside, ensuring that indoor air quality remains uncompromised. Both models feature Bradford-White's patented hydrojet total performance system, improving heat transfer by minimizing sediment buildup. This technology prolongs the lifespan of the unit while maximizing energy efficiency.

The PDV80S250, like its PDV counterparts, also utilizes direct venting technology for enhanced safety and efficiency. With an 80-gallon capacity and a robust 250,000 BTU input, this model is designed for businesses and larger households requiring significant hot water availability. The use of cutting-edge insulation technology in these models reduces standby heat loss, which translates to substantial savings on energy bills.

Lastly, the PDV802200 stands out with similar advanced features but offers a higher capacity of 80 gallons, making it a perfect solution for commercial applications. It strikes a balance between performance and reliability, ensuring consistent hot water delivery even during peak demand. The integration of robust safety features and user-friendly controls make it easy for facility managers to operate and maintain.

In summary, whether you opt for the D80T725 or one of the PDV models, you can expect a blend of performance, efficiency, and advanced technology. Bradford-White's commitment to quality and innovation ensures that each product meets the demands of modern consumers, making them a leading choice in the water heating industry.