Electric Instantaneous Water Heaters
Series Three (Single Phase)
Model | kW | Voltage | Current |
| Temperature Rise °F |
| Recommended |
| ||
Number | Rating |
| Per | 1.5 | 2.0 | 2.5 | 3.0 | 4.0 | Wire Size | |
|
|
| Phase | GPM | GPM | GPM | GPM | GPM |
|
|
28.0 | 240 | 3x40 Amps | — | — | — | 65 | 50 | 8 AWG |
|
This unit can only be ordered with 240V, but can be used on 208V with 25% reduced output (no model number change required).
Please specify your application when you place your order. Example:
SPEC OPTIONS:
T2T = Hot or Cold Water Feed
Min Flow 0.7 GPM
Max Flow 4.5 GPM
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only.
Whole House Residential up to 4.5 GPM (Apartment, Condo, Cabin).
1514"
Specifications:
Dimensions: 151⁄4"x 121⁄4"x 41⁄4"
Weight: 12 lbs. Materials:
Cover: Enameled Steel. Glass reinforced “UDEL†” Heater Body and Ni Chrome Element
Color: White
Element: Triple replaceable cartridge inserts
Operating Pressure: Min 45 PSI, Max 150 PSI.
1214"
714"
OUTLET | INTLET |
414" | ELECTRICAL |
| SUPPLY |
Series Four (Single Phase)
| Model | kW | Voltage | AMPS |
|
| Temperature Rise °F |
| Recommended | |||
| Number | Rating |
|
| 1.0 | 2.0 | 2.5 | 3.0 | 4.0 | 5.0 | 6.0 | Wire Size |
|
|
|
|
| GPM | GPM | GPM | GPM | GPM | GPM | GPM |
|
| 38.0 | 240 | 160 (4x40 Amps) | 129.8 | 129.8 | 103.8 | 86.5 | 64.9 | 51.9 | 43.3 | 8 AWG |
Please specify your application when you place your order. Example:
SERIES FOUR
SPEC OPTIONS:
T2T2 = Hot or Cold
feed staged
This unit can only be ordered with 240V, but can be used on 208V with 25% reduced output (no model number change required).
Specifications: | Color: White |
Dimensions: 203⁄16"x | Element: Four replaceable cartridge |
121⁄8"x 41⁄8" | inserts |
Weight: 23 lbs. | |
Materials: | at the bottom of the unit. |
Cover: Enameled Steel. | Operating Pressure: Min 45 PSI, |
Glass reinforced “UDEL†” Heater | Max 150 PSI. |
Body and Ni Chrome Element |
|
Min Flow 0.7 GPM
Max Flow 6.0 GPM
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only.
Whole House Residential.
Multi Fixture up to 6GPM.
20316"
121 8"
931 32"
OUTLET | INTLET |
418" | ELECTRICAL |
SUPPLY |
4