Bradford-White Corp ES-4100 warranty Thermostatic Triple Module Models Three Phase, 1514, 1214 714

Models: ES-3500 ES-4100 ES-3000 ES-5500

1 6
Download 6 pages 2.67 Kb
Page 5
Image 5
Thermostatic Triple Module Models (Three Phase)

Electric Instantaneous Water Heaters Bradford White 208/120 Three Phase Units

Thermostatic Triple Module Models (Three Phase)

Model

kW

Voltage

AMPS

 

Temperature Rise °F

 

Recommended

Number

Rating

 

 

1.5

2.0

2.5

3.0

3.5

4.0

Wire Size

 

 

 

 

GPM

GPM GPM GPM GPM GPM

 

 

EFT-18000-2-T-10 18.0

208y/120v

50.0

82

61

49

41

35

32

10

AWG

EFT-24000-2-T-10 24.0

208y/120v

67.0

82

65

54

47

41

10

AWG

EFT-18000-6-T-10 18.0

480y/277v

21.7

82

61

49

41

35

32

10

AWG

EFT-24000-6-T-10

24.0

480y/277v

28.9

82

65

54

47

41

10

AWG

EFT-32000-6-T-10

32.0

480y/277v

38.5

87

73

62

55

8

AWG

Min Flow 0.7 GPM Bradford White 480/277 Three Phase Units

Max Flow 4.0 GPM

Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.

Refer to Voltage Identification Code Chart and wiring diagram on page 5.

Multi-Outlet Three Phase Applications: Modular Hand Washing, Multi-Shower, Restaurants, Beauty Salons.

Please specify your application when you place your order.

Example: EFT-32000-6-T-10-S (Sanitation 180°F).

Please specify your application when you place your order. Example: EFT-24000-2-T-10-T2T

(Hot or Cold Water Feed)

1514"

SPEC OPTIONS:

S = Sanitation 180°F ML = Multi-Lav temp

setting 105 to

110 - 0.5 turn on up to 8 lavs

T2T = Hot or Cold feed staged turn-on, max 4.0GPM

FS = Factory Set (ambient to 180°F)

Specifications:

Dimensions:

151⁄4"x 121⁄4"x 41⁄4" Weight: 15 lbs. Materials:

Cover: Enameled Steel.

Glass reinforced “UDEL†” Heater Body and Ni Chrome Element Color: White

Element: Triple replaceable cartridge inserts Pipe-Fittings: 1/2" compression at bottom of unit.

Operating Pressure: Min 25 PSI, Max 150 PSI.

1214"

714"

OUTLET

INTLET

414"

ELECTRICAL

 

SUPPLY

Voltage Identification Code

For All Models

Voltage Code

1

2

3

4

5

6

7

8

Voltage

120

208

220

240

277

480

380

415

Example: ES-5500-4-S-10-S

The 4 in the model number indicates 240 volt.

Please be advised that the voltages listed in the Voltage Identification Code may not be available for all models.

Additional voltages and wattages are available. For more information please consult factory.

Electrical Configurations and Requirements for Bradford White Three Phase Tankless Water Heaters.

All Bradford White three-phase units are custom made to order and as such are, non-returnable and non-refundable. We urge you therfore to check your electrical supply, making sure all criteria for operating your Bradford White water heaters are met, especially that a neutral line is available for all 480/277 volt units.

Bradford White 208/120 Three Phase Units

L1

Delta Configuration

 

Requires: 3 Lives, 1 Ground (earth)

 

 

L2

Three-Phase delta; Three-wire

L3

 

Bradford White 480/277 Three Phase Units

Star Configuration

Requires: 3 Lives, 1 Neutral and

1 Ground

Three-Phase star; Four-wire; non-earthed neutral

L1

N

L2

L3

5

Page 5
Image 5
Bradford-White Corp ES-4100, ES-3500, ES-5500, ES-3000 warranty Thermostatic Triple Module Models Three Phase, 1514, 1214 714