Bradford-White Corp M-2-50T6DS Service Procedure RE-III, Water In Tank Is Cold With Power on

Models: M-2-50T6DS

1 40
Download 40 pages 46.16 Kb
Page 16
Image 16

SERVICE PROCEDURE RE-III

Residential Thermostat Testing

Single Element Operation or

Double Element, 4 Wire, Simultaneous, Single Phase Operation.

WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Water In Tank Is Cold With Power ON.

1.This procedure assumes line voltage, ECO and elements are in working order.

2.Turn power “ON” to water heater.

3.Set multi-meter to “Volts AC”.

4.Check across terminals L4 and T2 of thermostat (see illustration 6).

A) Rated voltage NOT present,

 

 

Recheck ECO. If ECO is okay,

 

 

replace thermostat.

 

 

B) Rated voltage IS present,

 

 

proceed to next step.

 

 

5. Check across element terminals

 

 

(see illustration 7).

 

 

A) Rated voltage NOT present,

Illustration 6

Illustration 7

check wire connections from

 

 

thermostat to element.

 

 

B) Rated voltage IS present,

 

Repeat element testing

 

see page 15.

 

Water Temperature In Tank Is Above Thermostat Setting.

 

1. This procedure assumes line voltage, ECO and

 

elements are in working order.

 

2. Turn power “ON” to water heater.

 

3. Set multi-meter to “Volts AC”.

 

4. See illustration 6 above, check across terminals L4 and T2

 

of thermostat.

 

A) Rated voltage IS present,

 

replace thermostat.

 

B) Rated voltage NOT present,

 

thermostat is okay.

Reference 4 Wire, Simultaneous, Single Phase

C) Lower than rated voltage IS present,

Wiring diagram.

recheck for grounded element

(see page 15).

NOTE: Wiring consists of two single element configurations

 

 

operating independently.