SERVICE PROCEDURE RE-IV
Light Duty Commercial
Thermostat Testing
Double Element,
Water In Tank Is Cold With Power ON.
1.This procedure assumes line voltage, ECO and elements are in working order.
2.Turn power “ON” to water heater.
3.Set
4.Check across terminals L4 and T2 of upper thermostat (see illustration 41).
A)Rated voltage NOT present, Recheck upper ECO. If ECO is okay, replace thermostat.
B)Rated voltage IS present, proceed to next step.
5.Check across element terminals (see illustration 42).
A)Rated voltage NOT present, check wire connections from thermostat to element.
B)Rated voltage IS present, Repeat element testing see page 15.
WARNING
High voltage exposure. Use caution to avoid
personal injury during this procedure.
Illustration 41 | Illustration 42 | |
|
|
|
Tank Does Not Deliver Enough Hot Water.
1.This procedure assumes line voltage, ECO and elements are in working order.
2.Turn power “ON” to water heater and set
3.Adjust temperature setting of upper & lower thermostat to the Highest setting. Water temperature in tank must be below thermostat setting for this test.
4. See illustration 41 above. Check voltage across terminals L4 & T2 of upper thermostat.
A) Rated voltage IS present, okay, upper thermostat is calling |
|
for heat. Go to step 5 below. |
|
B) Rated voltage NOT present, replace upper thermostat. |
|
5. Adjust temperature setting of upper thermostat to the minimum |
|
setting. Water temperature in tank must be above thermostat setting |
|
for this test. |
|
6. Check voltage across terminals L3 & T4 of upper |
|
thermostat (see illustration 43). |
|
A) Rated voltage NOT present, replace upper thermostat. |
|
B) Rated voltage IS present, upper thermostat is okay. Go to | Illustration 43 |
step 7 on next page. |
Page 29
29