GENERAL INFORMATION

Surface Mounted Thermostats

Surface mounted thermostats are mounted into a bracket which holds the thermostat against the side of the tank. Surface mounted thermostats respond to tank surface temperatures to sense a call for heat, set point temperature settings and high limit (ECO) activation. It is import that the entire back surface of the thermostat is in full contact or flush with the tank. Improperly mounted thermostat will lead to improper heater operation.

Manual

ECO (high limit)

Reset button

Temperature

 

Temperature

control Dial

 

control Dial

Surface Mount

Surface Mount

Surface Mount

Combination Thermostat/

Combination Thermostat/

Thermostat

ECO (high limit)

ECO (high limit)

59T Series

89T Series

89T Series

 

Direct Immersion “Screw-in” Type Heating Element

1-½ Hex

 

Terminal Block

Screw-in Flange

 

 

 

Zinc Plated Copper or

Incoloy Sheath

Terminal Block

Element Rating Ink Stamped

Screw

on side of Terminal Block.

 