Bradford-White Corp UDH65T45FR*N, UDH75T50FR*N, UDH165T*FRN, UDH1504T*FRN, UDH175S*FRN Line Pressure

Models: UDS150S*FRN UDH75T50FR*N UDH175S*FRN UDH1504T*FRN UDH50T45FR*N UDS140S*FRN UDH65T45FR*N UDH165T*FRN Ultra Low NOx Direct Vent Water Heater

1 28
Download 28 pages 17.13 Kb
Page 12
Image 12

The Bradford White

SERVICE PROCEDURE V

Gas Control

Testing, Disassembly & Replacement

Honeywell Gas Control Testing, Disassembly, and Replacement

The Gas Control is made up of (5) major components; the control cover, the piezo igniter, the valve body, the temperature sensor, and the back plate. The Gas Control is designed so that any of these components may be replaced without replacing the entire Gas Control.

Gas Control

Valve Body

Backplate

Cover

 

 

Gas Control

Cover Screw

Piezo Igniter

 

Temperature

 

Sensor

 

Valve Body

Insertion Stick

 

Screw

 

 

LINE PRESSURE

The Gas Control is designed for a maximum line pressure of 14.0" w.c. and a minimum line pressure of 1.0" w.c. over the water heater’s rated manifold pressure (check rating plate). Line pressure must be checked with the main burner on and off to assure proper readings.