Step 2: Mounting Unit to Wall

 

17" Chase-Mounted Five-Sided Stainless Steel combination Unit

Installation Instructions

COMBI5500

 

 

Installation Instructions continued . . .

Step 2: Mounting Unit to Wall

NOTE: Refer to Figure 2 when mounting unit. Unit is shown without valves and filler for clarity.

1.Insert six 1/2"-13 threaded studs (supplied by installer) into the back of the unit and screw in approximately 1/2".

2.Connect the 1-1/2" flush valve supply pipe (supplied by installer) to the 1-1/2" NPT inlet half coupling located on the back of the fixture.

3.Sliding studs and pipes through the wall openings, position the fixture in place (top of integral toilet seat is 15" above finished floor).

4.Secure the fixture to the wall using anchor brackets, washers, and nuts provided.

NOTE: All fasteners must be securely tightened to approximately 30 ft./lbs.

VALVE MOUNTING

PLATE

(159-292)

MOUNTING

CHANNEL

(140-558)

1/2"-13 THREADED STUD 0"-4" WALL (109-039) 4"-8" WALL (109-040) 8"-12" WALL (109-048)

WASHER

(142-002AM)

NUT

(110-119)

Figure 2

Bradley Corporation • 215-329 Rev. J; EN 04-732C