Express® Lavatory System - MG Series with Battery Infrared Control

Installation Instructions

MG-2/BIR3

 

 

Installation Instructions continued . . .

Step 2: Rough in wall anchors

1.Install six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “B” shown in Figure 1, 1a or 1b on pages 5-6).

NOTE: The dimensions for the wall anchors at location “A” are for reference only.

2.On the back of the bowl, measure the distance between the 3/4" bowl mounting holes. Divide this measurement in half. Measure and mark this dimension on the wall to the left of the centerline and to the right of the centerline. Install two 3/8" wall anchors with a minimum pull- out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “A” shown in Figure 1, 1a or 1b on pages 5-6).

NOTE: The anchors will be used to mount the Express® MG-2/BIR3 bowl and frame to the wall.

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY.

STUB OUT 2"

1-1/2" NPT DRAIN STUB OUT 2"

Figure 2

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

8/23/07

7

Page 7
Image 7
Bradley Smoker MG-2/BIR3 installation instructions Rough in wall anchors