Express® Lavatory System - MG Series with Battery Infrared Control

Installation Instructions

MG-2/BIR3

 

 

Installation Instructions continued . . .

Step 4: Install bowl assembly

IMPORTANT: See Figure 4 below when installing the bowl assembly. If the fixture has soap option, refer to the soap system installation manual 215-1585 before installing the bowl assembly.

1.With someone to assist you, place the bowl assembly squarely onto the frame being careful not to pinch tubing between bowl and frame.

2.Attach the front of the bowl assembly to the frame using the two 1/4-20 x 1/2" pan-head screws and washers provided. Do not tighten screws at this time.

IMPORTANT: When bolting the bowl assembly to the wall, do not overtighten the bolts. Overtightening bolts can damage the Terreon® material.

3.After the bowl assembly is attached to the frame, install the two 3/8" bolts and washers (supplied by the installer) to bolt the bowl to the wall anchors. Do not overtighten bolts.

4.Tighten the screws installed in procedure #2 above to secure the bowl assembly to the frame.

Do not overtighten.

5.If necessary, adjust sprayhead body to fit closely to wall by adjusting sprayhead mounting bolts. See Figure 8 on page 13 for sprayhead mounting bolt locations.

 

 

 

 

 

 

 

 

 

 

3/8" BOLT

 

 

FRAME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND WASHER

 

 

 

 

 

 

 

 

 

3/8" BOLT

 

 

SPRAYHEAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND WASHER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERREON®

END CAP (R)

Figure 4

1/4"-20 x 1/2"

PAN HEAD SCREWS AND WASHERS

(2) PLACES

BACK VIEW

BOWL

TERREON® END CAP (L)

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

8/23/07

9

Page 9
Image 9
Bradley Smoker MG-2/BIR3 installation instructions Install bowl assembly, Do not overtighten