34 Printer-Applicator-System PAM 3000
Special Settings for the Operation
There are integrated four DIP-switches to determine several types of operation. The DIP-
switches are located in the opening (1) at the right side of the printer.
Fig. 8e DIP-switches
1
DIP-switch Parameter ON OFF
1 Label format small large
2 Recycle part not installed installed
3 Applicator installed not installed
4 Print repeat no yes
DIP-switch 1-This switch is set on "ON" when small labels are used. By using large labels
the switch has to set on "OFF".
DIP-switch 2- If the switch is set on "ON" it is not possible to dispose the bad labels
recognized by a scanner at a recycle part.
If the switch is set on "OFF" it is possible to apply the bad labels on the recycle
part.
It is recommended to set the switch always on "ON" if no scanner is used.
DIP-switch 3- If the switch is set on "ON" the printer notices that there is an applicator to carry
out the further steps after printing.
If the switch is set on "OFF" it is necessary to guarantee the correct further
processing of the applying process by other features for example manually or
by industrial robots.
DIP-switch 4- If the switch is set on "ON" a bad label recognized by a scanner will not printed
again.
If the switch is set on "OFF" the print of a bad label recognized by a scanner
will be repeated.
It is recommended to set the switch always on "ON" if no scanner is used.