SYSTEMS DESCRIPTIONS

Electrical (Continued)

Drift In Microswitch (Cam 1 - All RA300 Models)

Turn Cam #1 counter-clockwise to start Drift In function sooner (shut pump off).

Turn Cam #1 clockwise to start Drift In function later (allow ramp to stow further before pump shuts off).

Drift Out Microswitch (Cam 2 - All RA300 Models)

Turn Cam #2 clockwise to start Drift Out function sooner (shut pump off).

Turn Cam #2 counter-clockwise to start Drift Out function later (allow ramp to deploy further before pump shuts off).

Counter Microswitch (Cam 3 - All RA300 Models)

Turn Cam #3 clockwise to start Interlock sooner.

Turn Cam #3 counterclockwise to return Interlock signal later.

Power Down Microswitch (Cam 3 - "YP" Models Only)

Turn Cam #3 clockwise to begin power down sooner.

Figure L

3 2

1

Figure M

1

2

3

Figure N

1

2 3

Turn Cam #3 counterclockwise to delay power down.

Page 25

Page 27
Image 27
Braun RA300 service manual Figure L