TM
GE/AR80 Installation Manual
580-00519, rev A 34 of 40
4.1 Configuring Network Equipment
The networking equipment that is connected to the GE/AR80 should be checked to
ensure it operates properly over a wired connection. Once this has been confirmed it will
save troubleshooting steps after the radio is installed and connected to the network
equipment.
We strongly recommend the network equipment on both sides of the link be configured
as follows:
1000Mbps full-duplex
Port configured not to enter error-disable state due to link up/down transitions
(since these may occur during periods of very heavy rain)
For AR model only, ensure to disable the, Installation Auto-Calibration selection
via Set Up GUI section, post installation.
4.2 Check Port Statistics on the Network Equipment
In the event the network equipment connected to the GE/AR80 offers the capability
below, we recommend you verify the following on the network equipment:
Link integrity
There are no receive errors on the link
Network traffic is flowing in both directions
* For pricing and a quotation, visit MeridianMicrowave.com
* For pricing and a quotation, visit MeridianMicrowave.com