900W Generator

Figure 13 — Service Spark Plug

• Reinstall spark plug.

Service Air Cleaner

Your engine will not run properly and may be damaged if you run it using a dirty air filter element.

Check the air filter every use and clean or replace the paper air filter element every 50 hours of operation or every three months, whichever comes first. Clean or replace more often if operating under dusty or dirty conditions.

To clean or replace air filter element:

Loosen the air cleaner cover screws, remove the air cleaner cover, and remove the element (see item number 4, exploded view on page 22.

Wipe clean the inside of the filter housing and cover thoroughly.

Wash the element in a solution of household detergent and warm water, then rinse thoroughly. Or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly.

Figure 14 – Service Spark Arrester Screen

Muffler Tail Pipe

Spark Arrester

Screen

Spark Arrester

Attachment Screw

Use a brass or stiff-bristle brush to remove carbon deposits from the spark arrester surface.

Inspect the spark arrester for breaks or tears and replace it if necessary.

NOTE: If you need to order a new spark arrester, please call 1-800-743-4115.

• Install the clean screen in the reverse order of removal.

NOTE: If you use your generator on any forest-covered, brush-covered or grass-covered unimproved land, it must have a spark arrester installed. The spark arrester must be maintained in good condition by the owner/operator.

STORAGE INSTRUCTIONS

Soak the element in clean engine oil and squeeze out the excess oil. DO NOT twist. The engine will smoke during initial start-up if too much oil is left in the element.

NOTE: If you need to order a new air filter element, please call 1-800-743-4115.

Reinstall the air cleaner element and the cover. Hand tighten the air cleaner cover screws.

Clean Spark Arrester Screen

The engine muffler is equipped with a removable spark arrester screen. Inspect and clean the screen every

10 hours of operation or every three months, as shown in Figure 14:

Loosen the screw on the muffler tail pipe and remove the spark arrester screen.

Transporting and Storage

When transporting the generator, turn the engine switch to “Off” and the fuel valve to “Close”. Keep the generator level to prevent fuel spillage.

WARNING! Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine cool before transporting or storing the generator.

Take care to not drop or strike the generator when transporting. DO NOT place heavy objects on the generator.

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

13