PowerBOSS™

5000W Portable Generator

MAINTENANCE

 

 

 

SPECIFICATIONS

Maximum Surge Watts . . . . . . . . . . . . . . . . . .6,250 watts Continuous Wattage Capacity . . . . . . . . . . . .5,000 watts Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0 Rated Maximum Continuous AC Load Current:

At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .41.7 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 5 U.S. gallons Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 158 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: Should you have questions about replacing components on your PowerBOSS™ generator, please call 1-800-743-4115for assistance.

Engine Maintenance

See engine owner’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

12

Page 12
Image 12
Briggs & Stratton 030222 Specifications, General Maintenance Recommendations, Engine Maintenance, Generator Maintenance

030222 specifications

Briggs & Stratton 030222 is a powerful and versatile portable generator designed to deliver reliable performance, making it an ideal choice for both home use and outdoor activities. With a robust design and advanced technology, this generator is built to handle a variety of situations, including emergency backup power, camping trips, and recreational activities.

One of the standout features of the Briggs & Stratton 030222 is its impressive power output. Equipped with a reliable engine, this generator can provide up to 2,500 watts of starting power and 2,000 watts of running power. This makes it capable of powering essential appliances such as refrigerators, lights, and more during an outage, ensuring that you remain comfortable and connected.

The generator features a durable frame that enhances its stability and longevity. It is built with high-quality components that withstand the rigors of transportation and variable weather conditions. Additionally, it includes built-in wheels and a handle for easy maneuverability, allowing users to effortlessly transport it to their desired location.

The Briggs & Stratton 030222 leverages advanced inverter technology, which not only delivers clean and stable power but also reduces noise levels, making it quieter than traditional generators. This is particularly beneficial for recreational use, where noise restrictions may apply. The inverter technology also ensures that sensitive electronic devices, such as laptops and phones, are protected from voltage spikes.

Another notable characteristic is its fuel efficiency. With an extended runtime, the generator can operate for hours on a single tank of gasoline, minimizing the need for frequent refueling. This feature is particularly advantageous during camping trips or long power outages.

Safety is also a priority in the design of the Briggs & Stratton 030222. It incorporates multiple safety features, including overload protection and low oil shutdown, which ensures that the engine does not sustain damage from running with insufficient oil. This adds an extra layer of reliability, giving users peace of mind during operation.

In summary, the Briggs & Stratton 030222 is an efficient and reliable portable generator that meets the power demands of various situations. With its strong power output, advanced inverter technology, fuel efficiency, and safety features, it stands as a solid choice for those in need of a dependable source of electricity, whether for home emergencies or outdoor adventures.