WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

When adding or draining fuel:

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

When starting equipment:

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

When operating equipment:

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

When transporting or repairing equipment:

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

When storing fuel or equipment with fuel in tank:

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

WARNING

Unintentional sparking can result in fire or electric shock.

When adjusting or making repairs to your generator:

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

When testing for engine spark:

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See Don’t Overload Generator.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or contact Briggs and Stratton.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

3

Page 5
Image 5
Briggs & Stratton 030235-01 manual When adding or draining fuel, When starting equipment, When operating equipment

030235-01 specifications

The Briggs & Stratton 030235-01 is a key component in the realm of outdoor power equipment, renowned for its reliability and performance. This model is primarily designed for use in portable generators, offering a powerful and efficient engine that meets the demands of users looking for dependable energy solutions.

One of the standout features of the 030235-01 is its impressive engine output. With a robust design, it provides a reliable source of power for various applications, whether for home backup during outages or for job sites requiring portable energy. This model is built with a reliable four-stroke engine, allowing for smooth operation and reduced emissions compared to two-stroke engines. This makes it an environmentally friendly option for those needing outdoor power.

The motor is equipped with advanced technologies that enhance its performance. The overhead valve (OHV) design optimizes engine efficiency while maintaining low operating temperatures, ensuring longer life and reduced wear. Additionally, the engine features a splash lubrication system, taking care of critical components to minimize friction and ensure a smooth operation even under heavy loads.

Another key characteristic of the Briggs & Stratton 030235-01 is its easy-starting capability. Many users appreciate this feature, especially during emergencies when time is of the essence. The primer bulb and choke system facilitate a hassle-free startup, allowing users to get the engine running with minimal effort.

Durability is also a key focus of this engine's design. Constructed with high-quality materials and comprehensive engineering, the 030235-01 can withstand the rigors of frequent use. It has a sturdy build that resists corrosion, making it suitable for various outdoor conditions. Coupled with routine maintenance, this generator can serve users for years to come.

On the ease of use front, the Briggs & Stratton 030235-01 is designed for straightforward operation. It has an intuitive control panel that enables users to manage their power needs without any confusion, enhancing the overall user experience.

In summary, the Briggs & Stratton 030235-01 stands out for its powerful engine output, innovative technologies such as OHV design and splash lubrication, durability under various conditions, and user-friendly operation. This combination makes it a preferred choice for those seeking reliable portable power solutions.