PowerBOSS™ | 5500W Portable Generator | TROUBLESHOOTING |
|
|
|
TROUBLESHOOTING
Problem | Cause | Correction | |||
|
|
|
|
| |
| 1. | One of the circuit breakers is | 1. | Reset circuit breaker. | |
|
| open. |
|
| |
No AC output is available, but | 2. | Fault in generator. | 2. | Contact Authorized service facility. | |
3. | Poor connection or defective cord | 3. | Check and repair. | ||
generator is running. | |||||
| set. |
|
| ||
|
|
|
| ||
| 4. | Connected device is bad. | 4. | Connect another device that is in | |
|
|
|
| good condition. | |
|
|
|
|
| |
Generator runs good at | 1. | Short circuit in a connected load. | 1. | Disconnect shorted electrical load. | |
|
|
|
| ||
but "bogs" down" when loads are | 2. | Generator is overloaded. | 2. | See "Don't Overload Generator". | |
connected. | 3. | Shorted generator circuit. | 3. | Contact Authorized service facility. | |
| |||||
|
|
| |||
Generator will not start; or starts | Low oil level. | Fill crankcase to proper level or place | |||
and runs rough. |
|
| generator on level surface. | ||
|
|
|
|
| |
Generator shuts down during | 1. | Out of fuel. | 1. | Fill fuel tank. | |
2. | Low oil level. | 2. | Fill crankcase to proper level or | ||
operation. | |||||
|
|
| place generator on level surface. | ||
|
|
|
| ||
|
|
| |||
Generator lacks power. | Load is too high. | See "Don't Overload Generator". | |||
|
|
|
|
|
14