MAINTENANCE

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and openings on the generator.These openings must be kept clean and unobstructed.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

ENGINE MAINTENANCE

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Oil

Oil Recommendations

NOTE: When adding oil to the engine crankcase, use only high quality detergent oil classified “For Service SF, SG, SH, SJ” or higher. DO NOT use special additives.

1.Choose a viscosity according to the following table:

NOTE: Synthetic oil meeting ILSAC GF-2,API certification mark and API service symbol with “SJ/CF ENERGY CONSERVING” or higher, is an acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals.

SAE 30: 40 °F and higher (5 °C and higher) is good for all purpose use above 40°F, use below 40°F will cause hard starting.

10W-30:0 to 100 °F (-18 to 38 °C) is better for varying temperature conditions.This grade of oil improves cold weather starting, but may increase oil consumption at 80°F(27°C) or higher.

*Check oil level frequently at higher temperatures.

Synthetic 5W-30:-20 to 120 °F (-30 to 40 °C) provides the best protection at all temperatures as well as improved starting with less oil consumption.

5W-30:40 °F and below (5 °C and below) is recommended for winter use, and works best in cold conditions.

Checking Oil Level

Oil level should be checked prior to each use or at least every 5 hours of operation. Keep oil level maintained.

1.Make sure generator is on a level surface.

2.Remove oil dipstick and wipe dipstick with clean cloth. Replace and tighten dipstick. Remove and and check oil level.

3.Verify oil is at “Full” mark on dipstick. Replace and tighten dipstick.

Adding Engine Oil

1.Make sure generator is on a level surface.

2.Check oil level as described in “Checking Oil Level”.

3.If needed, slowly pour oil into oil fill opening to the “Full” mark on dipstick. DO NOT overfill.

4.Replace and tighten dipstick.

Servicing Air Cleaner

Your engine will not run properly and may be damaged if you run it with a dirty air cleaner.

Replace the air cleaner every 25 hours of operation or once each year, whichever comes first. Replace more often if operating under dirty or dusty conditions.

14

Page 14
Image 14
Briggs & Stratton 030319, 030320 operating instructions Engine Maintenance, Oil, Servicing Air Cleaner

030319, 030320 specifications

Briggs & Stratton has been a trusted name in the power equipment industry for over a century, and their 030320 and 030319 models are perfect examples of their commitment to quality and innovation. These engines are designed to power a variety of outdoor equipment, including lawn mowers, generators, and pressure washers, making them a versatile choice for homeowners and professionals alike.

One of the main features of the Briggs & Stratton 030320 and 030319 engines is their impressive power output. The 030320 model boasts a robust 550cc displacement, while the 030319 offers a slightly lower 450cc. This power enables these engines to tackle demanding tasks with ease, ensuring that users can complete their projects efficiently and effectively.

Both models are equipped with advanced technologies that enhance performance and reliability. The ReadyStart system allows for effortless starting without the need to prime or choke the engine, significantly reducing the time spent preparing the equipment for use. Additionally, the engines feature a durable overhead valve (OHV) design, which promotes better fuel efficiency and reduced emissions compared to traditional side-valve engines.

Another key characteristic of the Briggs & Stratton 030320 and 030319 engines is their robust construction. They are built with high-quality materials, which provide durability and longevity, making them suitable for heavy-duty applications. The engines also feature a steel crankshaft that withstands high-stress conditions and a cast iron sleeve for improved wear resistance.

Maintenance is made easy with these engines, thanks to their accessible oil drain and air filter design. Users can quickly change the oil and replace the air filter, ensuring that the engine functions at peak performance over time. This focus on user-friendly maintenance makes the 030320 and 030319 models ideal for individuals who want reliable performance without the hassle of complicated upkeep.

Safety is also a priority in the design of these engines. They come equipped with features such as a low-oil shutdown system that automatically turns off the engine when oil levels drop too low, preventing potential damage. This added layer of protection ensures that users can operate their equipment with peace of mind.

In summary, the Briggs & Stratton 030320 and 030319 engines combine power, efficiency, durability, and user-friendly features. Whether you are a homeowner tackling seasonal yard work or a professional in need of reliable equipment, these engines deliver exceptional performance and reliability, solidifying Briggs & Stratton’s reputation as a leader in the industry.