Features and Controls

Read this Operator’s Manual and safety rules before operating your generator.

Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

A

T

 

 

S

 

R

 

P

 

N

B

 

C

 

 

M

D

L

E

 

F

K

 

G

J

 

H

 

A - Battery Float Charger Jack — Use battery float charger to keep the starting battery charged and ready for use.

B - Start Switch — Push and hold in “Start” position for a maximum of 15 seconds during each start attempt, until engine starts.

C - Oil Fill Cap/Dipstick — Check and add engine oil here.

D - Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.

E - Choke Lever — Used when starting a cold engine.F - Data Tag — Provides model, revision, and serial numberof generator. Please have these readily available when calling for assistance.

G - Engine Identification — Provides model, type and code of engine. Please have these readily available if calling for assistance.

H - Air Cleaner — Protects engine by filtering dust and debris out of intake air.

J - Recoil Starter — Used to start the engine.

K - Engine Rocker Switch — Set this switch to run position (I) before using recoil starter. Set switch to stop position (O) to stop engine.

L - Fuel Valve — Used to turn fuel supply on and off to engine.

M - Grounding Fastener — Consult your local agency having jurisdiction for grounding requirements in your area.

N - Fuel Tank — Capacity of seven (7) U.S. gallons (26.5 L).

P - Circuit Breakers (AC) — The 120 Volt AC, 20A duplex receptacles are provided with "push to reset" circuit breakers to protect the generator against electrical overload.

R - 120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads.

S - Double Pole Circuit Breaker (AC) — The 120/240 Volt AC, 30A locking receptacle is provided with a double pole circuit breaker to protect the generator against electrical overload. This switch also controls all receptacles.

T - 120 Volt AC, 20 Amp, Duplex Receptacles — May be

used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool, and motor loads.

Items Not Shown:Oil Drain Plug — Drain engine oil here.