REFERENCE

TABLE OF CONTENTS

TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

EQUIPMENT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . 2

CUSTOMER RESPONSIBILITIES . . . . . . . . . . . . . . . . . . . . . 2

INSTALLER RESPONSIBILITIES . . . . . . . . . . . . . . . . . . . . . 2

IMPORTANT SAFETY RULES . . . . . . . . . . . . . . . . . . . . . . . 3

Hazard Symbols and Meanings. . . . . . . . . . . . . . . . . . . 3

INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Unpacking Precautions . . . . . . . . . . . . . . . . . . . . . . . . 6

Delivery Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Shipment Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Required Specialty Tools/Equipment . . . . . . . . . . . . . . 6

Home Generator System Location . . . . . . . . . . . . . . 6-7

Fuel and Electrical Inlet Dimensions . . . . . . . . . . . . . . 7

Lifting the Generator . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

Access Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

THE GASEOUS FUEL SYSTEM . . . . . . . . . . . . . . . . . . . 9-10

Fuel Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Fuel Pipe Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

SYSTEM CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Generator AC Connection System . . . . . . . . . . . . . . . 13

Grounding the Generator . . . . . . . . . . . . . . . . . . . . . . 13

Utility Control Circuit Connection . . . . . . . . . . . . . . . . 13

Fault Detection System . . . . . . . . . . . . . . . . . . . . . . . . 13

System Control Panel . . . . . . . . . . . . . . . . . . . . . . . . 14

BEFORE INITIAL ENGINE START-UP . . . . . . . . . . . . . . . . 14

Engine Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Battery Connection . . . . . . . . . . . . . . . . . . . . . . . . 14-15

Fuel Supply System . . . . . . . . . . . . . . . . . . . . . . . . . . 15

FUEL SYSTEM SELECTION. . . . . . . . . . . . . . . . . . . . . . 15-16

INITIAL START-UP (NO LOAD) . . . . . . . . . . . . . . . . . . . . . 16

Engine Adjustment . . . . . . . . . . . . . . . . . . . . . . . . 16-17

AUTOMATIC OPERATION SEQUENCE . . . . . . . . . . . . . . . . 18

SETTING EXERCISE TIMER . . . . . . . . . . . . . . . . . . . . . . . 18

INSTALLATION INSPECTION . . . . . . . . . . . . . . . . . . . . . . 18

Fuel Comparison Chart . . . . . . . . . . . . . . . . . . . . . . . 19

Size of Propane Tank Required at Various Temperatures

When Kept at Least Half Full . . . . . . . . . . . . 19

Copyright © 2006 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.

EQUIPMENT DESCRIPTION

This product is intended for use as an optional home generator system which provides an alternate source of electric power and to serve loads such as heating, refrigeration systems, and communication systems that, when stopped during any power outage, could cause discomfort, or the like. This product DOES NOT qualify for emergency standby as defined by NFPA 70 (NEC).

This manual contains installation, startup and adjustment instructions for a Home Generator System that supplies 120/240 Volt, single phase, 60Hz devices. The Home Generator System may be operated on LP or natural gas fuel. A separate operator’s manual (part number 194689GS) contains operating and maintenance instructions for this model.

Every effort has been made to ensure that the information in this manual is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve the system at any time without prior notice.

CUSTOMER RESPONSIBILITIES

Read and follow the instructions given in the Operator’s Manual, especially the section regarding selecting essential circuits.

Follow a regular schedule in maintaining, caring for and using your Home Generator System, as specified in the Operator’s Manual.

INSTALLER RESPONSIBILITIES

Read and observe the safety rules.

Refer to the list of recommended UL approved transfer switches that is compatible with the Home Generator System elsewhere in the carton.

Read and follow the instructions given in this Installation and Start-up Manual.

IMPORTANT: If operating the generator below 40°F, it is recommended that a battery and oil warmer be installed. If operating the generator below 32°F, a battery and oil warmer MUST be installed. Both items are available at your local servicing dealer.

2

Page 2
Image 2
Briggs & Stratton 40210 Table of Contents, Equipment Description, Customer Responsibilities, Installer Responsibilities

40229, 40204, 40213, 40234, 40210 specifications

Briggs & Stratton is a recognized leader in the small engine market, catering to both homeowners and professionals with a wide range of reliable engines. The models 40210, 40234, 40213, 40204, and 40229 are notable entries in this lineup, each designed to deliver power, efficiency, and durability for various applications.

The Briggs & Stratton 40210 is often appreciated for its compact size and robust performance in lawn care equipment. It features a 140cc engine with an overhead valve design that enhances fuel efficiency and reduces emissions. This model supports easy starting with its dependable pull-start system and is well-suited for pushing mowers and other light-duty machines.

In contrast, the 40234 model stands out with its 190cc engine, which provides an excellent power-to-weight ratio. This engine is engineered to tackle medium-duty tasks, making it ideal for residential lawn trimming and garden maintenance. The 40234 incorporates advanced features like a ReadyStart technology that eliminates the need for priming, allowing for a hassle-free starting experience in various weather conditions.

The Briggs & Stratton 40213 shares similarities with the 40234 but enhances user interaction and maintenance with a more user-friendly design. It employs a 163cc engine that combines optimal power with low vibration, ensuring smooth operation. This model is particularly favored for its extended runtime, enabling users to complete their lawn care jobs without frequent interruptions.

For those seeking a slightly less powerful option, the 40204 is an excellent choice. Featuring a reliable 125cc engine, it is designed for lighter applications. This model is particularly notable for its lightweight build, making it highly maneuverable and easy to handle for novice users and homeowners alike.

Lastly, the 40229 offers a balance between power and practicality, housing an 11.5 gross torque engine rated for robust tasks. This engine is crafted with innovative technologies that promote fuel efficiency while minimizing noise output, making it a favorite among environmentally conscious users. It also integrates user-friendly features, such as an easy-access air filter, which simplifies maintenance.

Across these models, Briggs & Stratton ensures high-quality construction and usability, with features like dual air filtration systems and durable components that withstand rigorous use. Each engine encapsulates the brand's commitment to innovation, performance, and reliability, catering to the diverse needs of consumers in the landscaping and outdoor maintenance sectors. Whether for small residential tasks or larger projects, these engines are designed to empower users with the performance they need to get the job done efficiently.