6 BRIGGSandSTRATTON.COM
Installation

Unpacking

Delivery Inspection
After removing the carton, carefully inspect the transfer
switch components for any damage that may have occurred
during shipment.
IMPORTANT: If loss or damage is noted at time of delivery,
have the person(s) making delivery note all damage on the
freight bill and affix his signature under the consignor’s
memo of loss or damage. If loss or damage is noted after
delivery, contact the carrier for claim procedures. Missing or
damaged parts are not warranted.
Shipment Contents
• Automatic Power Transfer Switch
• Installation and Operator’s Manual

Mounting Guidelines

The Automatic Transfer Switch is enclosed in a NEMA
Type 3R enclosure suitable for indoor/outdoor use.
Guidelines for mounting the Automatic Transfer Switch
include:
• Install the switch on a firm, sturdy supporting structure.
• The switch must be installed with minimum NEMA 3R
hardware for conduit connections.
• To prevent switch contact distortion, level and plumb the
enclosure. This can be done by placing washers between
the switch enclosure and the mounting surface.
• NEvER install the switch where any corrosive
substance might drip onto the enclosure.
• Protect the switch at all times against excessive moisture,
dust, dirt, lint, construction grit and corrosive vapors.
A typical installation of the Automatic Power Transfer Switch
is depicted. An alternative installation of the Automatic Power
Transfer Switch is also depicted. It is best if the transfer
switch is mounted near the utility meter, either inside or
outside. Discuss layout suggestions/changes with the owner
before beginning the system installation process.
Typical
Main
Distribution
Panel
Transfer
Switch w/
Service and
Generator
Disconnect
Hot
Water
Heater
Air
Conditioner
Contactor
Generator
Watt -
Hourmeter
— — — — — — Control Wiring
Disconnect Switch
Branch Circuits
Alternate
Main
Distribution
Panel
Transfer
Switch
Hot
Water
Heater
Air
Conditioner
Contactor
Generator
Watt -
Hourmeter
Emergency Branch Circuits
— — — — — — Control Wiring
Disconnect Switch
Branch Circuits
Emergency
Load
Center