Locking Features (Continued)

TO LOCK THE MOUNTING BRACKET:

1. Using needle-nose pliers, detach one locking pin from mounting bracket.

2. Insert the locking pin into the lock located on the pivoting hinge of the battery door.

3. When you attach the Alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.

TO UNLOCK THE MOUNTING BRACKET

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Heat Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.

Always discharge the branch circuit before servicing an AC or AC/DC Heat Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Alarms with battery back-up. Finally, press the test button to discharge the branch circuit.

1. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket.

2.Pry the Heat Alarm away from the bracket by turning both the screwdriver and the Heat Alarm counter- clockwise (left) at the same time.

WEEKLY TESTING

NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. The built-in test switch accurately tests the unit’s operation as required by Underwriters Laboratories, Inc. (UL).

If the Alarm ever fails to test properly, replace it immediately. Products under warranty may be returned to the manufacturer for replacement. See “Limited Warranty” at the end of this manual.

DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harm- ful to your hearing. When testing, step away when horn starts sounding.

It is important to test this unit every week to make sure it is working properly. Press and hold the test but- ton until the alarm sends a test command acknowledge “chirp” just before it sounds continuously (the unit will continue to alarm for a few seconds after you release the button). If it does not alarm, make sure it is receiving power and has a fresh battery, and test it again. If it still does not alarm, it should be replaced immediately.

When testing one unit, all interconnected alarms will sound. If they don’t, check the connection with power to the units turned off, restore power and try again. Test all units in a series, not just one. Using the test button is the ONLY correct way to test the Heat Alarm.

USING THE REMOTE CONTROL WEEKLY TEST/SILENCE FEATURE

Using the VOLUME or CHANNEL buttons on most remote controls, you can test or silence this Alarm from up to 12 feet away.

To Test (or Silence) the Alarm:

1.Make sure you have a clear path between you and the alarm, free of any obstructions.

2.Point the remote at the front of the Alarm.

3.Press the VOLUME or CHANNEL button for at least 2 seconds. You will hear a brief acknowledge “chirp” when the Alarm receives the test (or silence) command.

If the Alarm does not respond to your remote control:

You may be standing too far away.

Your remote may not be compatible.

You did not hold the button on your remote for at least 2 seconds.

REGULAR MAINTENANCE

This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly.

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

Test it at least once a week.

Clean the Heat Alarm at least once a month; gently vacuum the outside of the Heat Alarm using your household vacuum’s soft brush attachment. Test the Heat Alarm. Never use water, cleaners or solvents since they may damage the unit.

If the Heat Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.

Relocate the unit if it sounds frequent unwanted alarms. See “Locations to Avoid for Heat Alarms” for details.

When the battery becomes weak, the Heat Alarm unit will “chirp” about once a minute (the low battery warning). You should replace the battery immediately to continue your protection.

Choosing a replacement battery:

Your Heat Alarm’s battery back-up requires one standard 9V battery. The following batteries are acceptable as replacements. This list supplements the list on the Heat Alarm battery door: Eveready #522 (Energizer); Duracell #MN1604, MX1604 (Ultra). You may also use a Lithium battery like the Ultralife U9VL-J for longer service life between battery changes. These batteries are available at many local retail stores.

Actual service life depends on the Heat Alarm and the environment in which it is installed. Constant exposures to high or low temperatures or high humidity may reduce battery life. All the batteries specified above are acceptable replacement batteries for this unit. Use of a different battery may have a detrimental effect on Alarm operation. Regardless of the manufacturer’s suggested battery life, you MUST replace the battery immediately once the unit starts “chirping” (the “low battery warning”).

IF YOU SUSPECT A PROBLEM

Heat Alarms may not operate properly because of dead, missing or weak batteries, a build-up of dirt, dust or grease on the Heat Alarm cover, or installation in an improper location. Clean the Heat Alarm as described in “Regular Maintenance,” and install a fresh battery, then test the Heat Alarm again. If it fails to test properly when you use the test button, or if the problem persists, replace the Heat Alarm immediately.

If you hear a “chirp” once a minute, replace the battery.

If you experience frequent non-emergency alarms try relocating the Heat Alarm.

If the alarm sounds when no smoke is visible, try cleaning or relocating the Heat Alarm. The cover may be dirty.

If the alarm does not sound during testing, make sure it is receiving AC power from the household current.

Always discharge the branch circuit before servicing an AC or AC/DC Heat Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Heat Alarms with battery back- up. Finally, press the test button to discharge the branch circuit.

Do not try fixing the alarm yourself – this will void your warranty!

If the Heat Alarm is still not operating properly, and it is still under warranty, please see “How to Obtain Warranty Service” in the Limited Warranty.

4

Page 4
Image 4
BRK electronic HD6135FB user manual Weekly Testing, If YOU Suspect a Problem

HD6135FB specifications

The BRK electronic HD6135FB is an advanced electronic smoke and carbon monoxide alarm designed to provide reliable safety and peace of mind to households and businesses. This state-of-the-art device combines innovative technology with user-friendly features ensuring enhanced protection against deadly smoke and toxic gases.

One of the standout features of the HD6135FB is its dual sensor technology, which utilizes both photoelectric and ionization sensors. This combination allows for improved detection of different types of fires, including smoldering fires and fast-flaming fires. The photoelectric sensor effectively identifies slow-burning fires that produce large amounts of smoke, while the ionization sensor is quick to respond to fast-flaming fires. This integrated approach significantly increases the overall effectiveness and reliability of the alarm.

In addition to fire detection, the HD6135FB excels in carbon monoxide detection. CO is often referred to as the silent killer, as it is colorless and odorless, making it undetectable without a proper alarm system. The HD6135FB is equipped with a sensitive electrochemical sensor that identifies dangerous levels of carbon monoxide, ensuring timely alerts to occupants.

The alarm is designed with user convenience in mind. It features a built-in voice alarm that announces the type of danger detected, whether it’s smoke or carbon monoxide. This feature helps users swiftly identify the source of danger without confusion. Additionally, the alarm is equipped with a lithium battery backup, ensuring continuous operation during power outages and enhancing its reliability.

Installation of the HD6135FB is straightforward, with the option to be mounted on walls or ceilings. Its sleek design ensures that it blends seamlessly into any environment. The device also includes a test button for regular function checks, providing peace of mind that the unit is working correctly.

Furthermore, the HD6135FB has an advanced LED indicator that displays the status of the alarm. A green light indicates normal operation, while a red light alerts users to an active alarm condition. This visual feedback is crucial for quickly assessing the status of the device.

In summary, the BRK electronic HD6135FB smoke and carbon monoxide alarm combines dual sensor technology, reliable monitoring, and user-friendly features. Its robust design and advanced alert systems make it an essential addition to any safety plan, helping to protect lives and property from the dangers of fire and carbon monoxide exposure.