Broan installation instructions For help, call us toll, MODEL 902, 902WH, free, 982, 982WH

Models: 902 982 902WH 982WH

1 2
Download 2 pages 60.04 Kb
Page 1
Image 1
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

 

 

MODEL

OVERALL SIZE

 

For help, call us toll

NUMBER

W

H

D

 

902

16

20

43/4

MODEL: 902, 902WH,

free!

902WH

16

20

43/4

982, 982WH

1-800-637-1453

982

16

26

43/4

SURFACE MOUNTED

To register this product,

982WH

16

26

43/4

WOOD MEDICINE CABINET

 

 

 

 

visit www.broan.com

 

 

 

 

 

 

 

 

 

INSTALLATION

1.Carefully remove all packing material.

2.

Determine the location of cabinet on wall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The commonly accepted height of a medicine cabinet is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64” from the fi nished fl oor to the center of mirror area.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

However, adjust to comfortable height for your family. It is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

recommended that the cabinet be located so that the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mounting screws may be secured into wall studs to provide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

maximum strength.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

3.

Drill four (4) mounting holes (A) in cabinet back 11/2” from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

top and bottom of cabinet. One set of holes to be aligned with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wood stud, if stud is in convenient location.

 

A1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2"

4.

Mark wall through upper mounting holes in back of cabinet.

 

 

Draw a horizontal line connecting the top two mounting hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

markings. This line must be level and, if necessary, should be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adjusted by use of a carpenter’s level.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.Drill mounting holes into studs. Insert (4) mounting screws (customer supplied) through cabinet back and mount cabinet

securely to stud in wall. If studs are not at the desired

2

location, use molly bolts or toggle bolts.

MIRROR CARE

Use only clean warm water and a clean, soft, lint-free cloth.

DO NOT USE cleaners that contain solutions of ammonia, vinegar, or chlorine.

DO NOT USE powdered cleansers or steel wool.

Never spray cleaning agent directly on mirror, especially on exposed edges and mirror backing. Apply cleaner to soft cloth and wipe mirror. Dry mirror thoroughly.

Keep mirror dry. A well ventilated bath room is important.

A1 1/2"

For help, call us toll1

MODEL: 902, 902WH,3

SERVICE PARTS

Key

 

 

Part Number

 

No.

Description

902

902WH

982

982WH

1

Door Assm

A97015739

P902WH00

P98200

A97015740

2

Magnet

7253

7256

7253

7256

3

Bumpon

7189

7189

7189

7189

 

Door Strike

7254

7257

7254

7257

 

Hinge

99420608

99420609

99420608

99420609

 

 

 

 

 

 

Order replacement parts by “PART NUMBER” - NOT by “KEY NO.”

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its product that such products will be free from defects in materials or workmanship for a period of one year from the date of origi- nal purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any product or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one-year period as specifi ed for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WAR- RANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specifi c legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model number and part identifi cation and (c) describe the nature of any defect in the product or part. At all time of requesting warranty service, you must present evidence of the original purchase date.

Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027

(1-800-637-1453)