FIG. 6

INSTALL THE DUCTWORK

 

 

 

 

 

FIG. 5

DUCTED HOODS ONLY

 

ROOF CAP

 

 

NOTE: To reduce the risk of fire, use only

 

 

 

metal ductwork.

 

ROUND DUCT

1. Decide where the ductwork will run

 

 

 

between the hood and the outside.

 

 

 

2. A straight, short duct run will allow the hood

 

 

 

to perform most efficiently.

DECORATIVE

 

WALL

3. Long duct runs, elbows, and transitions

FLUE

 

CAP

 

 

 

will reduce the performance of the hood.

HOOD

 

 

Use as few of them as possible. Larger

 

ROUND

 

 

ducting may be required for best

 

 

ELBOW

performance with longer duct runs.

 

 

6”

4. Install a roof or wall cap. Connect round

24” TO 30” ABOVE

 

ADAPTER

metal ductwork to cap and work back to-

COOKING SURFACE

 

 

(see “INSTALL

 

 

wards hood location. Use duct tape to seal

MOUNTING

 

 

the joints between ductwork sections.

BRACKETS” section for

 

 

mounting restrictions)

 

 

INSTALL ELECTRICAL

 

 

 

 

 

 

 

 

8”

DUCTED and NON-DUCTED HOODS

 

 

4”

WARNING : Electrical wiring must be

 

 

 

done by a qualified person(s) in

 

 

 

accordance with all applicable codes and

 

 

 

standards. This range hood must be

 

 

 

properly grounded. Turn off electrical

 

17”-19”

power at service entrance before wiring.

 

 

 

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a

cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

WARNING - Improper grounding can result in a risk of electric shock.

Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

1.Plan where the hood will be located above the cook top. Refer to the “INSTALL MOUNTING BRACKET” section for hood mounting height options.

2.Run 2-wire plus ground power cable to a standard 2” x 4” wall outlet box and 3- blade, 125 volt, 15 Amp grounded receptacle. Fig. 6.

3.Mount the receptacle 17” to 19” above the bottom of the hood.

4.Locate the box and the receptacle within boundary shown and off center of the ductwork (to allow for power cord plug and flue clearance).

-8 -

Page 8
Image 8
Broan E55000 manual Install the Ductwork, Install Electrical, Ducted and NON-DUCTED Hoods