Broan E60000 Series Install The Hood, Connect The Wiring All Blowers, mounting strip

Models: E60000 Series

1 16
Download 16 pages 1.19 Kb
Page 11
Image 11
13. INSTALL THE HOOD
WALL ANCHORS LOCATION

13. INSTALL THE HOOD

CAUTION

 

Hold the hood until it is completely secured to the wood

 

mounting strip.

 

INTERNAL BLOWER(S) ONLY

MOUNTING SCREWS LOCATION

 

Run power cable to installation location. Remove the electrical compartment cover.

 

Insert the cable in the hood and tighten the wire clamp to secure the cable.

 

ALL INSTALLATIONS

HD0264

 

Rest the back cavity of the hood on the wood mounting strip.

Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4’’ (for 30’’ and

36’’ width hoods) or (6) screws (for 42’’ and 48’’ width hoods) provided at locations shown. Drill (3) 3/16’’ size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the three wall anchors with the remaining no. 8 x 3/4’’ screws and the (3) washers provided.

For a non-ducted installation, go to step 15, Connect the wiring.

14.ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)

Run power cable to installation location. For ducting through top of hood, existing plate remains in place on inside back of hood.

For ducting through back of hood, remove existing plate from inside back of hood and remove the rough-in plate from the top of hood. Attach the plate to inside top of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the rough-in plate to the back of hood so that the wiring box is located on the right side as you are facing the hood.

Connect ducting to rough-in plate as you are installing the rough-in plate. Use duct tape to make all joints secure and air-tight.

ROUGH-IN PLATE

ON TOP OF HOOD

WIRING

LOCKNUTS

COVER

mounting strip.LOCKNUTS 15. CONNECT THE WIRING (ALL BLOWERS)Manual background

HD0262 PLATE ON BACK OF HOOD

15. CONNECT THE WIRING (ALL BLOWERS)

!WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally.

Remove wiring cover from rough-in plate or electrical compartment and set aside.

INTERNAL BLOWERS: Connect cable into wiring box using wire connectors. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.

CAUTION

The ORANGE wire (A) is for make-up air device connection only. If there is no make-up air device, never remove the cap on the ORANGE wire end.

Reinstall wiring cover.

IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.

A

HE0088

- 11 -

Page 11
Image 11
Broan E60000 Series installation instructions Install The Hood, Connect The Wiring All Blowers, mounting strip