Broan E60000 Series installation instructions Remove Filters And The Grease Drip Rail, 1 2 1

Models: E60000 Series

1 16
Download 16 pages 1.19 Kb
Page 8
Image 8
5.CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY)

5.CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY)

Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.

VERTICAL DISCHARGE

HORIZONTAL DISCHARGE

NOTE: For ducted installation only.

1 1  2  3 2 6. REMOVE FILTERS AND THE GREASE DRIP RAIL 3

1 7.REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY) 2 Manual background 3

HR0021

Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag). NOTE: For a non-ducted installation, punch out the back electrical knock-out (B).

A

B

HD0250

 

6. REMOVE FILTERS AND THE GREASE DRIP RAIL

A.Remove tape on filters.

Remove filters from hood and set aside.

NOTE: It is recommended to start with the center one.

B.Remove tape on grease drip rail (1). Lift out grease drip rail and set aside.

 

1

A

B

HD0243

 

7.REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)

Remove the adapter (1), or adapter/damper, taped inside the hood.

Manual background 1

HD0287

- 8 -

Page 8
Image 8
Broan E60000 Series Remove Filters And The Grease Drip Rail, Choose The Openings Internal Blowers Hood Only, 1 2 1