2. MEASURE INSTALLATION

2. MEASURE INSTALLATION

Dimensions for the most common installation are illustrated beside.

The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.

Distances over 30” are at the installer and users discretion.

 

 

 

 

 

 

 

 

 

 

 

Ceiling

Cabinet, soffit,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of wood

decorative flue or

 

 

 

 

 

 

A

 

 

 

 

 

 

mounting strip

non-duct kit flue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A + 2’’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hood

 

 

 

Minimum distance between the hood and cooktop:

24’’

Recommended maximum distance between the hood and cooktop: 30’’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard 36”

 

HH0093A

 

 

high cooktop

 

 

 

 

 

 

 

 

 

MINIMUM AND MAXIMUM DISTANCE

OVER COOKTOP

3. PREPARE THE INSTALLATION

CAUTION

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

Remove the installation kit from inside the hood. Make sure that the following items are included: -Wood strip (attached to back of hood)

-Installation manual

-Accessories including:

Baffle filters: 30” and 36” hoods comes with 3 baffle filters; 42” and 48” hoods comes with 4 baffle filters

Baffle filters handles (taped inside the hood)

3¼” x 10” adapter/damper (included with internal single blower hood)

4½” x 18½” adapter (included with internal double blower hood)

In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)

Bag of parts including:

(4)flat head screws no. 10-2’’, (8) screws no. 8 x 3/4’’, (2) wire connectors, (3) wall anchors,

(3)washers 13/64’’ ID x 3/4’’ OD, (1) wire clamp, (8) mechanical screws no. 8-32 x 1/4”, (4) no. 8 x 3/8” screws Parts sold separately:

-In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)

-Exterior blower assembly 331H, 332H, 335 or 336

-Shielded GU10 50W halogen bulbs (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width)

-RMP Series Backsplash (optional)

-ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)

-AEE Series Decorative flue, to be installed over the hood (optional)

-Transitions, duct, elbows, dampers, wall and roof caps.

Refer to pages 3 and 4 for a complete list of venting options and model numbers.

- 6 -