Broan ERV90HCS, HRV90HS installation instructions Maintenance

Models: ERV90HC HRV90HS HRV90H ERV90HCS

1 26
Download 26 pages 38.21 Kb
Page 23
Image 23
9. MAINTENANCE

9. MAINTENANCE

!WARNING

Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source.

Since this guide covers both HRV and ERV units, top and side ports, the illustrations shown in the maintenance procedures are typical. The following procedures applies for both HRV and ERV units.

Refer to pictures below to identify the inner parts of your unit.

33

 

 

 

 

4

 

 

 

 

1

 

2

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

VB0078

 

 

 

 

1)

HRV core

3)

Foam filter brackets

2)

Core retainers

4)

Foam core filters

 

3

 

 

 

3

 

 

 

 

4

 

 

 

 

1

 

2

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

VB0077

 

 

 

 

1)

ERV core

3)

Foam filter brackets

2)

Core retainers

4)

Foam core filters

9.1SEMI-ANNUAL MAINTENANCE

1. Unplug the unit.

VD0005

!WARNING

Be careful before opening the door; water or small debris could fall out. For HRV unit, always wait one minute after disconnecting the unit before opening the door in order to allow water to drain out from the unit.

2.Unlatch the door and open it. Clean the inner side of the door with a damp cloth, then wipe with a dry one. Disengage the door from its hinge by sliding it from left to right and set aside.

VD0179

!WARNING

Always hold the core when rotating the 2 core retainers; failure to do so will cause the core to fall out.

3.Lift both foam filters bracket (1) and remove the foam filters from the core. While holding the core, rotate the 2 core retainers (2) and slide out the core from the unit.

Manual background1 1

2 Manual background

VD0177

- 23 -

Page 23
Image 23
Broan ERV90HCS, HRV90HS installation instructions Maintenance