1. TECHNICAL DATA

1. TECHNICAL DATA

1.1AIR DISTRIBUTION (NORMAL OPERATION)

 

HRV

 

ERV

EXHAUST AIR-

FRESH AIR

EXHAUST AIR

 

 

FRESH AIR

FROM BUILDING

FROM OUTSIDE

FROM BUILDING

 

FROM OUTSIDE

FRESH AIR

EXHAUST AIR

FRESH AIR

 

 

EXHAUST AIR

TO BUILDING

TO BUILDING

 

 

TO OUTSIDE

TO OUTSIDE

 

 

 

 

 

 

 

 

 

 

 

 

VF0038

 

VF0039

 

 

 

 

 

 

 

 

1.2AIR DISTRIBUTION (RECIRCULATION OR DEFROST MODE)

 

 

HRV

 

ERV

EXHAUST AIR-

 

 

EXHAUST AIR-

 

FROM BUILDING

 

 

FROM BUILDING

 

FILTERED AIR

 

 

FILTERED AIR

 

TO BUILDING

 

 

TO BUILDING

 

 

VF0036

 

 

VF0037

 

 

 

 

 

 

 

Outside Temperature

HRV and ERV Defrost Cycles

 

Celcius (°C)

 

Fahrenheit (°F)

Defrosting (min.)

Operation time (min.)

 

 

 

 

 

between each defrost cycle

 

-5 to -27

 

23 to -17

9

23

 

-27 and less

 

-17 and less

10

22

1.3 SPECIFICATIONS

Model

HRV

 

ERV

Weight

42 lb (19 kg)

 

45 lb (20.4 kg)

Oval Ports

Fit 5” (127 mm) ducts

 

Fit 5” (127 mm) ducts

 

Drain Diameter

1/2” (12 mm)

 

N/A

 

Installation

Chains, springs and hooks (provided with the unit).

 

Motor Speeds

High and low speed

 

 

Electrical supply

120 V, 60 Hz

 

120 V, 60 Hz

Power Consumption

150 watts

 

160 watts

 

 

 

 

 

 