LOGIC DIAGRAM

WIRING DIAGRAM

LOGIC DIAGRAM

powersource

ofRiskelectrical

.6WIRING

 

FAN MOTORS SPEED SELECTION

SETTING

 

 

 

 

FAN SPEEDS

Factory shipped

JU1

3 2

1

Low - High

 

 

 

Low-Med select

JU1

3

2

1

Low- Med

 

 

 

 

BK

M3

.6WIRING BK

Damper motor

Line voltage factory wiring

Class 2 low voltage factory wiring

Class 2 low voltage field wiring

J3

A2

DAMPER

1 2

2 1

5 4 3 2 1

ELECTRONIC ASSEMBLY

J2

J1

 

120 V, 60Hz

 

 

120V, 60Hz

.

 

DIAGRAM

Line

 

 

 

Neutral

 

J10-2

HI MED

J10-1

shocks.

 

1

2

3

A1

 

 

 

JU1

F1

 

 

 

 

 

 

 

J9-1

K2

K1

Exhaust fan motor

 

 

 

 

 

Before

 

J9-2

 

 

 

J5-1

 

 

J9-3

 

 

 

J5-2

 

 

 

 

 

J5-3

 

 

J9-4

 

 

 

Exhaust fan motor

 

 

 

 

 

capacitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

Defrost

 

 

 

 

T1

 

Door interlock switch

 

 

 

 

 

 

 

 

 

 

 

temperature sensor

 

 

 

BK

120 V

 

(magnetically actuated

 

 

 

 

 

 

24 V

 

reed switch)

 

 

 

 

 

 

 

BL

90 V

 

 

 

R1

 

 

 

 

 

 

 

 

 

 

 

R

68 V

class 2

 

 

 

 

 

 

 

 

 

 

 

9.5 V

 

 

 

 

 

 

 

 

 

 

W neutral

 

W

W

 

 

 

Field wiring

 

 

 

class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

remote control

 

 

 

 

 

 

Y BN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see notes 3 & 4)

 

 

G

 

 

 

Y

BN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B G R Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhaust fan

 

BK

J5

 

5 4 3 2 1

 

 

 

 

 

 

 

motor

M1

BL BN

J8

 

 

 

 

 

 

 

 

1

 

 

 

10

 

 

- 20-

 

 

 

2

JU1

3 2

1

 

J11

 

9

 

 

Exhaust fan

 

 

3

 

J13

8

 

Override

 

 

 

 

 

 

 

 

BK

2

MED HI

 

 

7

 

motor

C1

1 2

 

ICP

6

 

switch

BK

1

 

 

J12

5

 

 

capacitor

 

J7

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5

 

3

 

(optional; see

 

 

 

 

 

J9

 

 

 

2

 

 

Supply fan

 

BK

J6

 

 

 

 

1

 

notes 3 & 4)

 

 

 

 

 

 

 

 

J14

 

 

motor

C2

BK

2

 

4 3 2 1

 

 

 

 

 

 

capacitor

 

1 See note 1 2

1

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

Supply fan

 

BK

2

F1 J10

 

 

ELECTRONIC

 

 

 

 

3

 

 

Furnace blower interlock

 

motor

M2

BL BN

J4

 

 

 

 

ASSEMBLY

A1

 

 

 

 

 

 

J14-1 : NO

 

 

 

G

 

 

BK

 

 

 

 

 

J14-2 : COM

 

 

 

 

 

 

 

 

 

 

 

J14-3 : nc

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(optional; see notes 3, 5)

 

 

 

 

120 V, 60 Hz W1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

NOTES

 

 

 

 

 

 

Critical characteristic.

 

 

 

1. For continued fire protection. Use specified UL listed/CSA

 

 

 

 

 

 

 

 

 

 

 

Certified line fuse.

 

 

 

 

 

 

 

COLOR CODE

 

 

 

2. If any of the original wire, as supplied, must be replaced,

 

 

 

 

use the same equivalent wire.

 

 

 

 

 

BK

BLACK

 

 

 

3. Field wiring must comply with applicable codes,

 

BL

BLUE

 

 

 

 

BN

BROWN

 

 

 

ordinances and regulations.

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

GREEN

 

 

 

4. Remote controls (class 2 circuit) available,

 

 

 

 

 

 

 

 

R

 

RED

 

 

 

see instruction manual.

 

 

 

 

 

W

WHITE

 

 

 

5. Furnace fan circuit must be class 2 circuit only.

 

Y

 

YELLOW

 

 

 

 

 

 

 

 

 

 

nc

no connection

 

VE0130A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J7-2

 

 

performing

 

 

 

 

 

J7-1

 

 

 

 

 

 

K3

Supply fan motor

 

 

 

 

 

J4-1

 

J4-2

 

 

 

 

 

J4-3

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply fan motor

 

 

 

 

 

any

 

 

 

 

 

J6-2

capacitor

 

 

 

 

 

 

 

 

 

 

 

 

J6-1

 

 

 

 

 

 

 

 

 

maintenance

! WARNING

 

 

 

J12-5

J2-5

A2

 

 

 

 

J12-4

J2-4

 

 

 

 

 

 

 

 

 

K4 J12-3

J2-3

 

Damper motor

120 V

24 V

J8-1

J12-2

J2-2

J3-2

 

90 V

J8-2

J12-1

J2-1

J3-1

 

 

or

 

68 V

class 2

J8-4

 

 

Door interlock switch

 

 

9.5 V

 

 

 

 

 

J8-5

J11-2

 

servicing,

 

neutral

class 2

 

 

 

 

J11-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K2

K5

J14-3

Furnace

 

 

 

 

K4

 

blower

 

 

 

 

 

J14-1

 

 

 

 

K5

 

interlock

 

 

 

 

 

 

always

 

 

 

 

 

 

(optional; see

 

 

 

 

K1

 

J14-2

 

 

 

 

 

 

notes 3, 5)

 

 

 

 

K3

 

 

 

 

 

CPU

 

J14-4

Override

 

 

 

 

 

 

 

 

 

 

 

 

J14-5

switch

 

 

 

 

 

 

disconnect the unit from its

 

 

 

 

 

 

(optional; see

 

 

 

 

 

 

J14-6

 

 

 

 

 

 

notes 3, 4)

 

 

 

 

 

 

J14-7

 

 

 

 

 

 

Field wiring

 

 

 

 

 

 

J14-8

 

 

 

 

 

 

remote

 

 

 

 

 

 

J14-9

 

 

 

 

 

 

control (see

 

 

 

 

 

 

J14-10

 

 

 

 

 

 

notes 3, 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 