OPERATION

Controls

The hood is operated using the (4) pushbuttons located at eye-level, on the front edge of the hood.

The light switch turns the halogen lamps on and off.

The blower on-low / off switch turns the blower on to its lowest running speed.The blower must be turned on using this switch. Turn the blower off by pressing this switch a second time.

LIGHT BLOWER

SWITCH MEDIUM SPEED

BLOWER BLOWER

ON-LOW / HIGH

OFF SPEED PILOT

SWITCHLAMP

The blower medium speed switch changes the blower speed to medium. This switch works only if the blower is already running at low or high speed.

The blower high speed switch changes the blower speed to high.This switch works only if the blower is already running at low or medium speed.

The pilot lamp lights up whenever the blower is on.

HALOGEN BULBS

This range hood requires two halogen bulbs (Type T4, 12V, 20W).

ALWAYS SWITCH OFF THE ELECTRICITY

SUPPLY BEFORE CARRYING OUT ANY

OPERATIONS ON THE APPLIANCE.

To change bulbs:

 

1. Loosen the ring nut by turning it

 

counterclockwise.

RING NUT

2.Remove the bulb by pulling sideward (DO

NOT ROTATE). CAUTION: BULB MAY BE

HOT!

3.Replace with Type T4, 12V, 20W halogen bulb. Do not touch replacement bulb with bare hands!

FUSE REPLACEMENT

SWITCH OFFTHE ELECTRICITY SUPPLY.

Remove the grease filters.

Remove the electrical box support and open the fuse box.

Replace with the same type of fuse (5x20mm, 4A, 125V).

ELECTRICAL

BOX

SUPPORT

FUSE

- 10 -