MODEL • L300KMG
TYPICAL INSTALLATION
MOUNTING (New Frame Construction) | |
8” ROUND DUCT | Mounting brackets |
| |
| |
| position for ½” |
| ceiling material. |
ADDITIONAL |
|
1½” FRAMING | CEILING JOIST |
| (16” centers shown) |
Blower | MOUNTING |
in horizontal | SCREW |
discharge position. |
|
GRILLE |
|
Install after |
|
ceiling is |
|
finished. | GRILLE |
| |
| SCREW |
Page 2
TYPICAL INSTALLATION
WIRING
BLACK
TO
BLACKTOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
WIRING
PLATE
WHITE
TO
WHITE
120 VAC LINE IN
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
DUCTING (Horizontal blower discharge)
MOUNTING (Existing Frame Construction) |
2 X 4 FRAMING |
(wide side down) |
8” ROUND DUCT |
CEILING JOIST |
(16” centers |
shown) |
MOUNTING |
BRACKETS |
ROOF CAP
8”
ROUND
DUCT
8”
ROUND ELBOW
WALL |
CAP |
(Attached to | FINISHED |
opposite sides | CEILING |
of housing & | MATERIAL |
| |
so housing is |
|
flush with |
|
finished ceiling) |
|
GRILLE | GRILLE |
| SCREW |
Two ways to connect ductwork to a
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating the ventilator.