DeLonghi DEGESC24SS Wire Power Cord Installation using Strain Relief Supplied

Models: DEGESC24SS

1 24
Download 24 pages 30.22 Kb
Page 17
Image 17
3-Wire Power Cord Installation using Strain Relief Supplied

3-Wire Power Cord Installation using Strain Relief Supplied

(See Figures 3.1 and 3.2)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws.

2.Insert the Power Cord through the Bracket; then tighten the Power Cord by using the Strain Relief. Allow enough slack to easily attach the cord terminals to the Terminal Block.

3.Remove the 3 wire terminal nuts and washers from the Terminal Block.

4.Plug the terminal holes of Power Cord. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.

5.Plug washers and tighten nuts securely.

6.Assemble the Terminal Block Access Plate. Do not remove Ground strap.

6.Assemble the Terminal Block Access Plate.

4-Wire Power Cord Installation using Strain Relief Supplied

(See Figures 3.1 and 3.3)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 3.1).

2.Insert the Power Cord through the Bracket; then tighten the Power Cord by using the Strain Relief. Allow enough slack to easily attach the cord terminals to the Terminal Block.

3.Remove the 3 wire terminal nuts and washers from the Terminal Block.

4.Remove the Ground Strap from the frame of range and ter- minal by removing its screw and cutting it as shown in Figure 3.3.

5.Plug the terminal holes of Power Cord. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires

must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the 4-Wire Power Cord Installation using Strain Relief Supplied (Ground) identified Grounding Screw.

6.Plug washers and tighten nuts securely.

7.Assemble the Terminal Block Access Plate.

Screws

Fig. 3.1

 

Terminal Block

 

Access Plate

 

Fig. 3.2

Terminal Block

Ground strap

Neutral Wire

Power Wires

Bracket

Power Cord

Strain Relief

 

Fig. 3.3

Terminal Block

Cut Ground Strap

 

Grounding Wire

Neutral Wire

 

Power Wires

 

Bracket

Grounding Screw

 

Power Cord

Strain Relief

 

17

Page 17
Image 17
DeLonghi DEGESC24SS Wire Power Cord Installation using Strain Relief Supplied, Assemble the Terminal Block Access Plate