CONVERSION TO LP/PROPANE GAS
Every range is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
SETTING THE PRESSURE REGULATOR (fig. 2.6)
The pressure regulator is accessible by removing the warmer drawer; the pressure regulator is positioned on the rear right side of the range (fig. 2.9).
To remove the warming drawer:
1.Open the drawer completely (fig. 2.6)
2.Move down the lever of left guide (fig. 2.7) and up the lever of right guide (fig. 2.8).
3.Remove the drawer; the levers have to be keep moved (fig. 2.6).
Fig. 2.8
2
3
2
Fig. 2.6
Fig. 2.7
13