ALLURE™ QS1 SERIES RANGE HOOD
Page 4
PREPARE THE HOOD
TOP RECTANGULAR |
| |
DUCT KNOCKOUT | ||
(Remove for 3¼” x 10” | ||
DUCT KNOCKOUT | ||
Vertical & for 7” Round | ||
(Remove for 7” Round | ||
Discharge) | ||
Discharge) | ||
|
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10” Horizontal Discharge)
11Remove appropriate Duct Knockout(s) from top or back of hood.
CONNECT WIRING
WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power
from being switched on accidentally.
HOUSE WIRING (120 VAC)
CARDBOARD (Use to protect cooktop)
UP TO 1” | TAPE | TOP/BACK |
EDGE | ||
|
| |
ADJUSTMENT |
|
|
PIVOT | DAMPER/DUCT |
| |
| CONNECTOR |
| (Vertical discharge |
| position shown) |
12 3¼” x 10” Ducted Discharge Only: Attach Damper/Duct Connector over knockout opening. Make sure damper Pivot is nearest to Top/Back Edge of hood. Remove Tape from damper flap.
137” Round Ducted Discharge Only:
from range hood).
1Connect House Wiring (120 VAC) to hood. Use a piece of Cardboard to protect the cooktop, if necessary.
GREEN
GROUND
SCREW
2Connect house black to hood black wire, house white to hood white wire, and house ground under Green Ground Screw.
Securely tighten cable clamp onto house wiring.
3 Replace wiring cover.
NOTE To accomodate