Broan RM519004 manual Operation, Halogen Bulbs, Controls, Heat Sentry

Models: RM519004

1 40
Download 40 pages 61.16 Kb
Page 11
Image 11
OPERATION

OPERATION

Controls

The hood is operated using the slide controls under the bottom of the hood.

The light switch turns the lamps on and off.

The blower switch :makes it possible to select the motor operating speed. Position 0: motor off.

The pilot lamp lights up whenever the blower is on.

LIGHT

SWITCHBLOWER SWITCH

PILOT

LAMP

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

HALOGEN BULBS

This range hood requires two halogen bulbs (Type T3, 12Volt, 20 Watt Max, G-4 Base).

ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONSON THEAPPLIANCE.

To change bulbs:

1.Loosen the ring nut by turning it counterclockwise.

2.Remove the bulb by pulling sideward(DO

NOT ROTATE). CAUTION: BULB MAY BE

HOT!

3.Replace with Type T3, 12Volt, 20 Watt Max, G-4 Base halogen bulb. Do not touch replacement bulb with bare hands!

-11 -

RING NUT

Page 11
Image 11
Broan RM519004 manual Operation, Halogen Bulbs, Controls, Heat Sentry, Not Rotate. Caution Bulb May Be Hot